SMT-BD2
3 - MAIN PROTECTIONS
3.1-D
ISPLAYED PROTECTIONS
PROTECTION
ERROR DISPLAY
LED*
Amplifier rated current overload
I
2
t
5
z
. blinking display = I
2
t warning threshold is reached (Idyn output)
z
z
. continuous display = I
2
t fault (amplifier inhibited in fusing mode)
Encoder cable interruption
Encoder
z
5
z
z
Encoder pulses counting error
Counting
5
5
z
5
Power stage failure:
Power stage
5
5
. power supply overvoltage
z
z
. internal overcurrent protection
. short-circuit between phases
. amplifier overtemperature
(220/04 to 220/60 current ratings and 400 VAC amplifier range)
Amplifier overtemperature
°C Amp
5
z
(only 220/70 and 220/100 current rating amplifiers)
5
z
Power supply undervoltage
Undervolt.
z
5
5
z
Motor overtemperature
°C Motor
5
5
5
z
Hall Effect Sensors or Sin/Cos commutation channels error
HES
z
z
5
z
Analog to Digital Conversion error
ADC
5
z
z
5
Speed following error
Tracking
z
z
z
5
Fault of the amplifier parameter storage
EEPROM
5
z
5
5
Amplifier automatic procedure:
Busy
5
5
. blinking display = procedure operating
5
5
. continuous display = operating error
*
z
= LED is unlit
5
= LED is lit.
All these faults are memory stored in the amplifier except for the "Undervolt." fault.
The reset of a stored fault can be made:
- by means of the RESET function in the
Visual Drive Setup
software
- via the fault RESET input (pin 13 of the X4 connector)
- by switching off the amplifier power supply.
14