GP-M45J-CX-01A
4005-CB, 4002-CB Manual
RD: JUN 2008
R.L. 02A
BA
LEAK TEST:
For your safety you must perform a leak test of all connections and hoses.
Ensure that the connection of gas hose to burner assembly is also leak tested.
Mix equal parts of water and soap, brushing mixture on all joints.
1. Ensure that the heater gas control knob is fully closed by turning
completely clockwise.
2. Open cylinder valve for Propane or supply line for Natural Gas.
3. Apply the soap solution generously to all connections and hoses.
Carefully examine all connections in the gas train.
If bubbles occur, there
IS
a leak. Close supply valve completely.
Retighten the leaking connection and repeat leak test process, until
ALL
leaking has ceased,
no matter how small
.
If the leak cannot be permanently repaired , close the cylinder valve completely and con-
tact a qualified and licensed gas technician for repair parts and service.
After successful leak test, ensure that the burner assembly and all other components are
securely fastened.
Lift the cylinder cover up from the base of the heater
Let cover rest on top of post supports in an angle position
Install a full gas cylinder on to the heater base
Connect the gas regulator to the QCC-1 cylinder valve by turning the connector knob
manually in a clockwise direction.
DO NOT use a tool, hand tighten only
Leak test the connection to the tank
(see below for instruction)
Replace the cylinder cover.
7. CONNECTION AND TESTING
:
PROPANE CYLINDER CONNECTION :
Page 7