clean cloth. Failure to dry all surface completely may cause water stains. There are also stainless steel 

cleaners available which can restore and preserve the finish of the steels protective layer. 

 

Return all accessories to their initial positions and plug the unit in. 

 

Early signs of stainless steel breakdown can consist of small pits and cracks. If this has begun, star to 

apply stainless steel cleaners in order to restore the passivity of the steel. 

 

Many  product  foods  have  an  acidic  content  which  can  attack  stainless  steel,  such  as  mustard, 

mayonnaise, lemon juice, tomatoes and other vegetables. 

 

NOTE: Never use steel pads, wire brushes or scrapers to clean the cabinet. 

 

NOTE:  Cleaning  solutions  need  to  be  alkaline  based  or  non-chloride  cleaners.  Any  cleaner 

containing chlorides will damage the protective film of the stainless steel. 

Cleaning the condenser coil 

The  condenser  coil,  which  is  located  directly  behind  the  rear  panel  grill,  must  be  checked 

periodically.  The  frequency  of  cleaning  depends  on  the  operating  environment.  Air  must  be  able  to 

freely  circulate  through  the  condenser,  so  the  surface  of  the  condenser  must  be  kept  free  of  dirt  and 

grease for proper system operation.  Dirty condensers result in compressor failure and product loss. If 

the condenser coil is dirty or blocked, follow this instruction: 

 

 

Disconnect the power supply 

 

Remove the lower grill on the rear of the cabinet  

 

In some models, it will be necessary to remove screws anchoring condensing unit to 

frame rails and carefully slide out.  

 

If the condenser has a housing cover, its screws must be removed. 

 

Carefully clean dirt from the condenser using a vacuum cleaner of soft brush; never use a wire brush.  

 

Heavier dust build up may require compressed air to blow through the condenser coil. 

 

Replace the condenser cover, slide condensing unit back into position and tighten all screws. 

 

Finally, replace the lower rear panel and reconnect electrical power supply. 

 

WARNING:  Never  use  water  for  this  cleaning  procedure  as  water  can  damage  the  electrical 

components located near or at the condenser coil.

 

 

Doors/Hinges Maintenance 

Over time and with heavy use doors the hinges may become loose. If it is noticed that the door 

is beginning to sag, it may become necessary to tighten the screws that mount the hinge brackets to the 

frame of the unit.  

 

Summary of Contents for VBZ Ibiza

Page 1: ...VBZ Ibiza Cases GELATO DISPLAY CASES Service Installation Manual...

Page 2: ...CEDURE 7 8 OPERATION 7 8 1 Temperature control adjustment 7 8 2 Defrost control 8 8 3 Loading product 10 9 MAINTENANCE CARE AND CLEANING 10 9 1 Cleaning procedure 10 9 2 Parts and Service Error Marcad...

Page 3: ...cluding the following This refrigerator must be properly installed and located in accordance with this manual before it is used Do not allow children to climb stand or hang on the shelves in the refri...

Page 4: ...nt This unit is intended for indoor use only Be sure the location chosen for your unit must be able to provide good air circulation for most efficient refrigeration Avoid locations near heat sources s...

Page 5: ...front side or back However you must be certain to allow the unit to remain in an upright position afterwards for at least 24 hours before plugging it in so that the compressor oil and refrigerant may...

Page 6: ...e should be checked before connection to assure that proper voltage for the cabinet wiring is available To determine correct unit voltage please refer to the serial data plate located on an inner wall...

Page 7: ...ercial standards If any unusual noises are heard turn the unit off immediately and check for any obstructions of the fans All cabinets must be given enough time to reach normal operating temperature b...

Page 8: ...Menu mode it is used to look through the parameter codes or decrease the value of the variable in use This turns the light on and off Note while in the OFF status the light button is active VBZ ice c...

Page 9: ...wo defrost cycles To adjust this parameter you may follow the next instruction 1 Enter the Programming mode by pressing the SET DOWN keys for 3s the C or F LED starts blinking 2 Select the required pa...

Page 10: ...binet Do not leave food inside the unit when it is going to remain shut down either from a power outage or fault in the equipment If the cabinet is going to remain shut down for prolonged periods try...

Page 11: ...st be able to freely circulate through the condenser so the surface of the condenser must be kept free of dirt and grease for proper system operation Dirty condensers result in compressor failure and...

Page 12: ...to back up and overflow the drain pans Many operating problems are derived from causes that can be easily eliminated without the need to contact the Technical Department The following page shows a ta...

Page 13: ...ective 3 Overload protector defective 4 High head pressure 5 Fan motor pump etc wire to wrong of overload protector Compressor starts but immediately cuts out on overload 1 Starting relay contacts poi...

Page 14: ...Fixture doors left open too long 8 Insufficient defective or water logged insulation 9 Evaporated oil logged Noisy unit 1 Compressor oil charge low 2 Fan cable on condenser or evaporator bent causing...

Page 15: ...r authorization by Infrico In addition to the warranty set above Infrico warrants the hermetically and semi hermetically sealed compressor part only for an additional four 4 years based on the install...

Page 16: ...pparatus is not functioning correctly users must make the checks indicated in the manual and if the problem persists contact their distributor This certificate must be presented if it is necessary for...

Page 17: ...improper or non compliant installation of the apparatus connection voltage power supply fluctuations electrical connection not conforming to instructions etc or from manipulation of the nameplate or o...

Page 18: ...___________ Compressor No __________________________ Vendor Signature Purchaser Signature R E T U R N T O T H E M A N U F A C T U R E R User ___________________________________________________________...

Page 19: ...Infrico SL CR CO 762 Los Piedros Las Navas s n 14900 Lucena C rdoba Espa a 00 34 957 59 51 16 office 00 34 957 59 51 06 fax asistenciatecnica infrico com info infrico com www infrico com...

Reviews: