background image

 

 

 15  

 

R

e

v

is

n

: 0

5

   

  R

e

f.:

 M

A

N

U

_

V

B

Z

   

 1

6

/0

2

/2

0

1

7

 

 

Infrico USA, Corp. (“Infrico”) warrants to the original customer that the Infrico brand equipment 

sold  hereunder,  except  for  parts  and  accessories  which  carry  the  warranty  of  a  supplier  (the 

“Equipment”) will be free from defects in material and factory workmanship under normal conditions of 

use  and  maintenance  for  a  period  of  (2)  two  years  from  the  Date  of  Installation  (Warranty 

Commencement Date), but in no event to exceed (27) months from the Date of Shipment. Warranty is 

Not Transferable. 

 

 

If  there  is  a  defect  in  material  or  factory  workmanship  covered  by  this  Warranty  reported  to 

Infrico during the period the applicable Warranty is in force and effect, Infrico will repair or replace, at 

Infrico’s  option,  that  part  of  the  Equipment  that  has  become  defective.  Infrico  will  cover  labor  cost 

within (2) years from the Warranty Commencement date or (27) months from shipment date, whichever 

occurs  first.  Infrico  shall  bear  all  labor  costs  in  connection  with  the  installation  of  these  replacement 

parts, provided that, the installation is conducted by Infrico or its authorized representative. Charges for 

warranty  travel  time  not  to  exceed  (2)  hours  or  up  to  (100)  miles  total.  Any  charges  exceeding  those 

stated herein must have prior authorization by Infrico. 

 

 

 

In addition to the warranty set above. Infrico warrants the hermetically and semi-hermetically 

sealed  compressor  (part  only)  for  an  additional  four  (4)  years  based  on  the  installation  date.  This 

warranty  is  for  defects  both  in  workmanship  and  material  under  the  normal  and  proper  use  and 

maintenance  service.  The  four  (4)  years  extended  warranty  only  applies  to  hermetically  and  semi-

hermetically  sealed  parts  of  the  compressor  and  does  not  apply  to  any  other  part  or  component, 

including,  but  no  limited  to  cabinet,  temperature  control,  refrigerant,  motor  starting  equipment,  fan 

assembly, or any other electrical or mechanical component.  

Parts Warranty Coverage: Infrico warrants all new case parts produced or authorized by Infrico 

to  be  free  from  defects  in  material  and  workmanship  for  a  period  of  (90)  days  from  the  Warranty 

Commencement Date. If any defect in material and workmanship is found to exist within the warranty 

period,  Infrico  will  replace  the  defective  part  without  charge.  Defective  parts  become  the  property  of 

Infrico. 

 

Infrico  will  have  no  responsibility  to  honour  claims  received  after  the  date  the  applicable 

Warranty  expires.  Notwithstanding  the  foregoing,  any  claim  with  reference  to  the  Equipment  or  any 

parts therefore for any cause shall be deemed waived unless submitted by the User to Infrico within (30) 

11.1

 

Two year parts & Labor warranty 

11.2

 

Warranty coverage 

11.3

 

Additional four year compressor part warranty 

Summary of Contents for VBZ Ibiza

Page 1: ...VBZ Ibiza Cases GELATO DISPLAY CASES Service Installation Manual...

Page 2: ...CEDURE 7 8 OPERATION 7 8 1 Temperature control adjustment 7 8 2 Defrost control 8 8 3 Loading product 10 9 MAINTENANCE CARE AND CLEANING 10 9 1 Cleaning procedure 10 9 2 Parts and Service Error Marcad...

Page 3: ...cluding the following This refrigerator must be properly installed and located in accordance with this manual before it is used Do not allow children to climb stand or hang on the shelves in the refri...

Page 4: ...nt This unit is intended for indoor use only Be sure the location chosen for your unit must be able to provide good air circulation for most efficient refrigeration Avoid locations near heat sources s...

Page 5: ...front side or back However you must be certain to allow the unit to remain in an upright position afterwards for at least 24 hours before plugging it in so that the compressor oil and refrigerant may...

Page 6: ...e should be checked before connection to assure that proper voltage for the cabinet wiring is available To determine correct unit voltage please refer to the serial data plate located on an inner wall...

Page 7: ...ercial standards If any unusual noises are heard turn the unit off immediately and check for any obstructions of the fans All cabinets must be given enough time to reach normal operating temperature b...

Page 8: ...Menu mode it is used to look through the parameter codes or decrease the value of the variable in use This turns the light on and off Note while in the OFF status the light button is active VBZ ice c...

Page 9: ...wo defrost cycles To adjust this parameter you may follow the next instruction 1 Enter the Programming mode by pressing the SET DOWN keys for 3s the C or F LED starts blinking 2 Select the required pa...

Page 10: ...binet Do not leave food inside the unit when it is going to remain shut down either from a power outage or fault in the equipment If the cabinet is going to remain shut down for prolonged periods try...

Page 11: ...st be able to freely circulate through the condenser so the surface of the condenser must be kept free of dirt and grease for proper system operation Dirty condensers result in compressor failure and...

Page 12: ...to back up and overflow the drain pans Many operating problems are derived from causes that can be easily eliminated without the need to contact the Technical Department The following page shows a ta...

Page 13: ...ective 3 Overload protector defective 4 High head pressure 5 Fan motor pump etc wire to wrong of overload protector Compressor starts but immediately cuts out on overload 1 Starting relay contacts poi...

Page 14: ...Fixture doors left open too long 8 Insufficient defective or water logged insulation 9 Evaporated oil logged Noisy unit 1 Compressor oil charge low 2 Fan cable on condenser or evaporator bent causing...

Page 15: ...r authorization by Infrico In addition to the warranty set above Infrico warrants the hermetically and semi hermetically sealed compressor part only for an additional four 4 years based on the install...

Page 16: ...pparatus is not functioning correctly users must make the checks indicated in the manual and if the problem persists contact their distributor This certificate must be presented if it is necessary for...

Page 17: ...improper or non compliant installation of the apparatus connection voltage power supply fluctuations electrical connection not conforming to instructions etc or from manipulation of the nameplate or o...

Page 18: ...___________ Compressor No __________________________ Vendor Signature Purchaser Signature R E T U R N T O T H E M A N U F A C T U R E R User ___________________________________________________________...

Page 19: ...Infrico SL CR CO 762 Los Piedros Las Navas s n 14900 Lucena C rdoba Espa a 00 34 957 59 51 16 office 00 34 957 59 51 06 fax asistenciatecnica infrico com info infrico com www infrico com...

Reviews: