8
R
e
v
is
ió
n
: 0
5
R
e
f.:
M
A
N
U
_
V
B
Z
1
6
/0
2
/2
0
1
7
The temperature is set at the factory but local conditions may need slight adjustment.
: This turns the condensing unit and lights off. There is still power to the controller.
: for displaying or modifying the set point. When displaying the maximum and minimum
temperature, these can be deleted by keeping the button pressed for 3 second.
This displays the maximum stored temperature; in programming mode and “Function
Menu” mode it is used to look through the parameter codes or increase the value of the variable in use.
This displays the minimum stored temperature; in programming mode and
“Function Menu” mode it is used to look through the parameter codes or decrease the value of the
variable in use.
: This turns the light on and off.
Note
: while in the OFF status, the light button is active.
VBZ ice-cream cases are designed and factory set to maintain an average cabinet temperature
of 2/6ºF.
Important: Recommend to switch off the ice-cream cases at night (during non-working hours).
This equipment is designed to conserve ice creams during the exhibition and sale hours, thereby we
prevent any potential blockage or products leaks as well as consuming an excess of energy.
The defrost timer is present for a defrost period by temperature.
Ice Cream cases, VBZ,
have a hot gas defrost system which works by routing superheated
compressor discharge gas directly to the evaporator, avoiding any accumulation of frost.
8.2
Defrost control