TITAN GO Product Manual |
Connectors Guide
INGENIA | 2022-07-14 08:35:14
30
•
•
•
6
STO_COLLECTOR
Safe Torque Off Feedback output signalling optocoupler
collector
Notes
In case you are not using STO functionality it must be bypassed. Connect STO_COMMON to GND of
connector P1. Connect both STO1 and STO2 to 24V_OUT of connector P1.
When STO is disconnected the power stage is totally disabled, including current sense amplifiers. It is not
possible to read motor phase current with this error active.
P3 Mating
Description
3.00mm Pitch, Micro-Fit™ 3.0 Receptacle Housing, 6 Circuits.
Image
Part number
Molex 43025-0600
Distributor code
Digi-Key WM1785-ND / Mouser 538-43025-0600 / Farnell 672907
Notes
See Micro-Fit 3.0 connectors mating for further information about crimping terminals and cables.
5.7 P4: Digital halls and motor temperature connector
P4 connector
8 pin 2 row Micro-Fit™ 3.0, 3 mm pitch header. Molex
Pin
Signal
Function
1
HALL_1
Digital Hall 1 sensor input
2
HALL_2
Digital Hall 2 sensor input
Summary of Contents for Titan GO
Page 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Page 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Page 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Page 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...