TITAN GO Product Manual |
Signalling LEDs
INGENIA | 2022-07-14 08:35:14
42
RUN LED
state*
Concept
Description
Off
Off
The device is switched off
Blinking
Pre-operational
The device is in state PREOPERATIONAL
Single flash
Stopped
The device is in state STOPPED
On
Operational
The device is in state OPERATIONAL
*See a detailed description of the states in the next table:
* Possible LED states
Description
ON
The LED is always on
OFF
The LED is always off
Single flash
One short flash (~200 ms) followed by a long off phase (~1000 ms)
Double flash
Sequence of 2 short flashes (~200 ms), separated by an off phase
(~200 ms).
The sequence is finished by a long off phase (~1000 ms)
Triple flash
Sequence of 3 short flashes (~200 ms), separated by an off phase
(~200 ms).
The sequence is finished by a long off phase (~1000 ms)
Blinking
On and off with a frequency of ~2.5 Hz: ON for ~200 ms followed
by off for ~200 ms.
Note that the specified timings can vary in up to ±20%.
6.3 Resolver status LEDs
6.3.1
Resolver LEDs
There are 2 LEDs close to the Resolver feedback connector. If the resolver is functioning correctly both LEDs should
be off. They turn on when there is a problem with the Resolver or the Resolver is disconnected.
LED
Colour
Meaning
LOT
Orange
Loss of Tracking. Indicates that it is not possible to follow the resolver
angle.
Summary of Contents for Titan GO
Page 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Page 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Page 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Page 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...