7.2 Power supply
The Titan Go Servo Drive is powered from the Supply, shunt and motor connector. An internal isolated DC/DC
converter provides the internal logic supply (+24 V
DC
) to the circuits as well as regulated 5 V output voltage to
supply feedback sensors and I/O. This power supply turns on at 60 V DC bus voltage.
7.2.1 Power supply requirements
The choice of a power supply is mainly determined by voltage and current ratings of the power supply. Main
requirements of the Titan Go power supply are:
The
voltage
should be the targeted for the motor. This means up to
400 V
depending on the Titan Go
variants. Make sure that the voltage rating of the power supply does not exceed the voltage rating of the
motor, otherwise it could be damaged.
The
current
should be the one able to provide the phase peak current of the application. This means up
to
200 A
depending on the Titan Go variants. Make sure that the current rating for the power supply is at
least as high as the motor.
The voltage and current range can be decreased due to the motor requirements.
Further information on how to dimension a power supply for the Ingenia drives can be found
.
7.2.2 Power supply connection
Titan Go power and logic supply are provided through the same terminal. However, the Aux supply connector can
be used to supply only the logic with a 24 V power supply (see below).
The following picture show the Titan Go supply wiring diagram using a single power supply. The logic supply is
internally generated.
Note that the minimum power supply voltage is 65 V if single supply is used.
•
•
•
Disconnection recommendations
Please follow the following recommendations:
The board could be hot during 5 min after disconnection.
Preferably do not disconnect the supply while having a motor in motion. The back EMF may create
dangerous voltages.
If working with Motion Lab with USB connection, preferably disconnect the drive from the
application before disconnecting. This prevents COM port corruption.
Twisted cables
Twisted power supply cables are preferred to reduce electromagnetic emissions and increase immunity.
Summary of Contents for Titan GO
Page 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Page 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Page 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Page 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...