7.8.2 RS485 interface
Titan Go Servo Drive supports
full duplex RS-485
. This means that independent differential lines are used for TX
and RX, which cannot be connected together.
Full-duplex RS485 is fully compatible with RS422
communication.
Main specifications of Titan Go RS485 interface are shown in the next table:
Specification
Details
Interface
Full duplex. Isolated (GND shared with CAN). Self-supplied (no
need for external supply)
Communication distance
Up to 1200 m
Baud rate
128 kbps to 460 kbps
Daisy chain
Supported
Termination resistor
120
Ω
termination resistor on RX channel
Next figure illustrates how to connect Titan Go Servo Drive with a host in a point to point configuration.
Multi-point connection
Titan Go Servo Drive RS485 interface is not intended for bus operation, since there is no collision
prevention protocol implemented. However,
multiple drives can be connected to the same master
using daisy chain connection
.
Multiple drive connection with daisy chain
must be configured using
Ingenia
suite.
For
allowing multi-point communication
each servo drive must be allocated a unique node ID
, and
daisy
chain option must be enabled.
Please, see
documentation for
further information.
Summary of Contents for Titan GO
Page 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Page 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Page 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Page 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...