7.8.2.1 Multi-point connection using daisy chain
Daisy chain connection is a multi-point network topology based on connecting multiple terminals in a ring. The
wiring consists on connecting the TX terminals of each device to the RX terminals of the next device. An example of
daisy chain wiring of multiple Titan Go is shown in the next figure.
Termination resistor
The use of
termination resistors at the RX side
of each differential pair (120
Ω
between RX+ and RX- of
both host and slave) is essential for correct operation of the RS485 communication.
For long cable
distances (> 10 m) a termination in the TX side
is also recommended.
Titan Go Servo Drive
includes TX and RX termination resistors on board.
They can be activated/
deactivated with the switches available near the connector. Another 120
Ω
termination resistor should be
placed at the end of Titan Go TX line (RX of the host). Suggested termination resistor: Xicon
Termination resistor for daisy chain
In daisy chain connection,
termination resistors are required in each link
. For short distances, a 120
Ω
termination resistor in the RX side is required. For long distances (> 10 m) it is required in RX and TX sides.
Titan Go Servo Drive
includes TX and RX termination resistors on board.
They can be activated/
deactivated with the switches available near the connector.
Summary of Contents for Titan GO
Page 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Page 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Page 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Page 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...