7.2.6 Power supply wiring recommendations
7.2.6.1 Wire section
The minimum wire section is determined by the current consumption and the allowed voltage drop across the
conductor. It is preferred to use
wide section stranded wires
to reduce impedance, power losses and ease the
assembly. Following table indicates recommended wire sections:
Connection
Minimum wire size
Maximum wire size
Stranded wire (preferred)
8.4 mm
2
(8 AWG)
33.6 mm
2
(2 AWG)
Solid wire
8.4 mm
2
(8 AWG)
33.6 mm
2
(2 AWG)
In case of using buss bars please take care not to exceed the terminal torque.
7.2.6.2 Wire length
The distance between the Titan Go Servo Drive and the power supply
should be minimized when
possible
. Short cables are preferred since they reduce power losses as well as electromagnetic emissions
and immunity.
For best immunity use twisted and shielded 2-wire cables for the DC power supply. This becomes crucial in
long cable applications.
Avoid running supply wires in parallel with other wires for long distances, especially feedback and signal
wires.
7.2.6.3 Supply protection
It is strongly recommended to use an over-current protection between the drive and the DC power supply. Both a
fuse or a DC circuit breaker can be used. Class B or Z would be prefered, typically rated for semiconductor, control
or photovoltaic applitations. Take the following as suggested parts:
Manufacturer
Part Number
Image
Description
ABB
125 A, 600 V
DC
circuit breaker.
ABB
125 A, 250 V
DC
, class B circuit breaker.
Summary of Contents for Titan GO
Page 19: ...TITAN GO Product Manual Product Description INGENIA 2022 07 14 08 35 14 19 ...
Page 56: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 56 ...
Page 89: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 89 ...
Page 101: ...TITAN GO Product Manual Wiring and Connections INGENIA 2022 07 14 08 35 14 101 ...