Triton Go Product Manual |
Wiring and Connections
INGENIA | 05/29/2017
59
61
http://www.digikey.es/product-detail/en/966067-1/A114629-ND/1152396
TE Connectivity
6 mm pin legth,
0.5 mm
2
(20 AWG)
Wire length
• The distance between the Triton Go Servo Drive and the power supply
should be minimized when
possible
. Short cables are preferred since they reduce power losses as well as electromagnetic
emissions and immunity.
•
For best immunity use twisted and shielded 2-wire cables for the DC power supply. This becomes crucial
in long cable applications.
•
Avoid running supply wires in parallel with other wires for long distances, especially feedback and signal
wires.
7.3 Motor and shunt braking resistor
7.3.1 AC and DC brushless motors
Brushless motors should be connected to phase A, B and C terminals. Note that some manufacturers may use
different phase name conventions (see Table below).
Phase name
Alphabetic
Numeric
UVW
PH_A
A
1
U
PH_B
B
2
V
PH_C
C
3
W