5.1.2
SKYLink Interface Com Port
This function allows selecting the com port type to have the interface link
operate on.
Perform the steps below to select the com port type on the ingenico terminal.
Step Terminal Display
Description
1.0
Press FUNC
2.0
FUNCTION?
Enter 6629 and press ENTER
3.0
INTERFACE
COM PORT
1-RS232
2-USB
Press the corresponding number key to select the appropriate interface com port
type followed by ENTER key.
1-RS232 (This will be selected if the interface link will be communicating via serial
cable)
2-USB (This will be selected if the interface link will be communicating via USB
cable. Please ensure to load the Telium USB driver
to allow the
communication to take place via USB cable)
4.0
RESET INTERFACE
Y/N
Press ENTER to reset the interface com port or CLEAR to exit out without resetting
the interface com port.
NOTE: In the event if the POS system is not communicating with the terminal,
please perform the above steps to reset the interface link and com port.
Repeat the same steps again to set it up with correct settings and save the
changes. After that, restart the terminal by pressing and holding down the
FUNC + CLEAR key for 2 seconds. This will reset the interface link and start
communicating with the POS system.