EN-2
80167596_ed1
EN
Torque Adjustment
To adjust the torque on these Twin Blade Impulse Wrenches, proceed as follows:
1. Remove the Adjustment Hole Plug.
2. Rotate the Drive Shaft until the Torque Adjustment Screw is visible in the opening.
3. Using a 1.5 mm hex wrench, rotate the Adjustment Screw
clockwise
to increase the
torque output and
counter-clockwise
to decrease the torque output. Do not rotate the
Oil Plug.
4. Replace the Adjustment Hole Plug.
NOTICE
Make all final adjustments at the job.
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest
Ingersoll Rand
Office or Distributor.