This manual is an integral part of the dryer you bought, and must remain with the machine even if this will be resold. 
It is highly recommended that the qualified*personnel for installation maintenance and/or control will fully comply with the 

contents of this manual and the prevention and safety rules in force in the country where the system will be used. In this way, 
not only the usage of the machine will be rational, but also the service will result cost effective. 

In case your dryer will present any kind of problem, please contact your local authorized Ingersoll Rand distributor. 
Please note that, when necessary, the use of original spare parts will ensure efficiency and long duration to your dryer. 
Due to the continuous technological evolution, Ingersoll Rand reserves the right to modify the specifications contained in this 

manual without giving previous notice.

 

SYMBOLS AND LABELS USED IN THE MANUAL AND ON THE DRYER 

 or 

 or 

 or 

 

Air inlet. 

 or 

 or 

 or 

 

Air outlet. 

 

Read the Operators manual before attempt to 
start up the machine and to perform any 
service operation on the dryer. 

 

Pay particular attention to components or 
systems under pressure. 

 

Pay particular attention to the indications 
preceded by these symbols. 

 

Pay particular attention to hot surfaces. 

 

Installation, maintenance, and/or control 
operations preceded by these symbols must 
be performed exclusively by qualified 
personnel

*

 

Pay particular attention to the risk of electric 
shock. 

 

Condensate drain point. 

 

Rotation direction of the fan. 

 

Attention: Before performing any 
maintenance operation on this 
machine, do not forget to disconnect 
the electric supply, to completely 
discharge air pressure, and to refer to 
the Operators manual 

 

 

 

* Qualified personnel must be trained and certified in accordance with local laws and regulations. 

WARRANTY 

The Company warrants that the equipment manufactured by it and delivered hereunder will be free of defects in material and 

workmanship for a period of twelve months from the date of placing the Equipment in operation or eighteen months from the 
date of shipment from the factory, whichever shall first occur. The Purchaser shall be obligated to promptly report any failure to 
conform to this warranty, in writing to the Company in said period, whereupon the Company shall, at its option, correct such 
nonconformity, by suitable repair to such equipment or, furnish a replacement part F.O.B. point of shipment, provided the 
Purchaser has stored, installed, maintained and operated such Equipment in accordance with good industry practices and has 
complied with specific recommendations of the Company. Accessories or equipment furnished by the Company, but 
manufactured by others, shall carry whatever warranty the manufacturers have conveyed to the Company and which can be 
passed on to the Purchaser. The Company shall not be liable for any repairs, replacements, or adjustments to the Equipment or 
any costs of labor performed by the Purchaser or others without Company's prior written approval. 

The effects of corrosion, erosion and normal wear and tear are specifically excluded. Performance warranties are limited to 

those specifically stated within the Company's proposal. Unless responsibility for meeting such performance warranties are 
limited to specified tests, the Company's obligation shall be to correct in the manner and for the period of time provided above. 

THE COMPANY MAKES NO OTHER WARRANTY OR REPRESENTATION OF ANY KIND WHATSOEVER, EXPRESSED 

OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE, ARE HERBY DISCLAIMED. 

Cod. 710.0138.39.00 Rev1A – 05.2008

 

2 - 28 

Summary of Contents for D108IN

Page 1: ...R DRYERS Operators Manual For 60 Hz dryers FR SECHEUR D AIR A EXPANSION DIRECTE Manuel des Op rateurs Pour des s cheurs 60 Hz D12IN D18IN D25IN D42IN D54IN D72IN D108IN D144IN D180IN D300IN D360IN Cod...

Page 2: ...sic Spare Parts 28 FR TABLE DES MATIERES 1 INFORMATIONS GENERALES 1 1 Description fonctionnelle 12 1 2 Utilisation du s choir en toute s curit 12 2 INSTALLATION 2 1 R ception et transport 13 2 2 Lieu...

Page 3: ...personnel must be trained and certified in accordance with local laws and regulations WARRANTY The Company warrants that the equipment manufactured by it and delivered hereunder will be free of defec...

Page 4: ...gree IP 42 Improper grounding can result in electrical shock and can cause severe injury or death This product must be connected to a grounded metallic permanent wiring system or an equipment groundin...

Page 5: ...rance 20 inches 500 mm around the dryer in order to allow an adequate cooling of the machine and for maintenance and or control operations The incoming air must be free from smoke or flammable vapours...

Page 6: ...ature is low and there is no compressed air load Variable speed fan control A patented microprocessor allows to adjust dryer s cooling capacity by changing the fan motor speed If the dew point is grea...

Page 7: ...machine 3 1 2 CONDENSATE DISCHARGE PARAMETERS PROGRAMMING Push the SET key for 10 seconds to enter the parameters configuration menu the display will show in sequence the set point value the code of...

Page 8: ...istributor ESA ES2 The automatic Energy saving mode activated due to low load Alarm output OFF Refrig Compressor output OFF Fan output OFF Drain cycle standard No action necessary Automatic Reset ASt...

Page 9: ...e switching the dryer on again in order to allow freon pressure to rebalance 4 MAINTENANCE TROUBLESHOOTING AND DECOMMISSIONING 4 1 MAINTENANCE Before attempting any maintenance operation make sure tha...

Page 10: ...internal thermal protection Wait one hour and check again If the fault persists stop dryer and call your local Ingersoll Rand distributor Problems with the electrical components of the compressor Che...

Page 11: ...OW PRESSURE IN THE LINE Air flows continuously through the condensate drainage Check the signal from the control board if it is continuous replace the control board TROUBLE DISPLAY POSSIBLE CAUSE REME...

Page 12: ...tte machine sans avoir coup l alimentation lectrique avoir purg compl tement l air sous pression et consult le manuel des op rateurs Le personnel qualifi doit tre form et certifi conform ment aux lois...

Page 13: ...ir point de ros e lev mais ne nuit pas la s curit Le circuit lectrique annexe B a un degr de protection minimum IP 42 Merci de noter que une mise terre incorrecte peut provoquer des chocs lectriques e...

Page 14: ...ventilateur Garantir suffisamment d espace libre autour du s choir 20 inches 500 mm pour permettre le refroidissement correct de la machine et pour les op rations d entretien et ou de contr le L air a...

Page 15: ...prim Commande de variation de vitesse du ventilateur Un microprocesseur brevet permet d ajuster la capacit de refroidissement du s cheur en variant la vitesse du moteur du ventilateur Si le point de c...

Page 16: ...ur la touche pendant 1 seconde active ou d sactive le processus Lorsque le processus est d sactiv l afficheur affiche le message OFF ATTENTION lorsque la carte lectronique indique OFF plusieurs compos...

Page 17: ...deur Ingersoll Rand local autoris ESA ES2 Option d conomie d nergie active Sortie alarme active Sortie compresseur inactive Sortie ventilateur inactive Sortie vacuation standard Aucune r initialisatio...

Page 18: ...Avant d effectuer toute op ration d entretien s assurer que 1 L installation n a pas de parties sous pression 2 L installation n a pas de parties sous tension UNE FOIS PAR SEMAINE OU TOUTES LES 40 HEU...

Page 19: ...ue remplacez les si le probl me persiste Activation de la protection thermique interne du compresseur Attendez une heure puis v rifiez nouveau Si la panne persiste arr tez le s choir et contactez votr...

Page 20: ...sur la carte de commande lectronique C8 et C9 PRESSION FAIBLE DANS LA LIGNE L air s coule en permanence travers l vacuation de la condensation V rifiez le signal provenant de la carte de commande s i...

Page 21: ...Evaporator Evaporateur F1 F2 Fuses Fusibles FD Air filter 10 micron Filtre air 10 micron FF Filter dryer Filtre d shydrateur FH Air filter 0 01 micron Filtre air 0 01 micron FP Air filter 1 micron Fil...

Page 22: ...ev 00 Models D300IN to D360IN Condensate drain Purge de condensant Air inlet Entr e de l air Air outlet Sortie de l air Refrigerant line Ligne r frig rant Compressed air line Ligne de l air comprim Co...

Page 23: ...B WIRING DIAGRAM SCHEMA LECTRIQUE Cod 714 0164 01 00 Rev 00 Models D12IN to D72IN 115V 1Ph 60Hz Cod 714 0165 01 00 Rev 00 Models D108IN to D180IN 115V 1Ph 60Hz Cod 710 0138 39 00 Rev1A 05 2008 22 28...

Page 24: ...Cod 714 0168 01 00 Rev 00 Models D300IN to D360IN 230V 1Ph 60Hz Cod 710 0138 39 00 Rev1A 05 2008 23 28...

Page 25: ...1 35 TOTAL A A 2 8 2 8 2 8 3 6 6 6 8 9 12 6 8 3 8 3 CONNECTION NPT 1 1 1 F 100 AIR T C 38 F 140 AIR T MAX C 60 F 100 AMB T C 38 F 36 122 AMB T MIN MAX C 2 50 psi 100 AIR W PRESS bar 7 psi 203 174 AIR...

Page 26: ...Temp entr e d air DISCH PRESS Discharge Pressure Pression de d charge AIR T MAX Max air inlet temperature Temp entr e d air max HP SWITCH SETTING High pressure switch setting R glage du pressostat de...

Page 27: ...ulation de l air Models D25IN to D180IN A B C D E F G H I L mm 390 432 441 100 85 65 45 65 20 12 D25IN to D72IN inches 15 3 8 17 17 3 8 3 15 16 3 3 8 2 9 16 1 3 4 2 9 16 13 16 7 16 1 2 NPT 1 2 NPT 6mm...

Page 28: ...G H mm 503 604 980 157 254 100 115 40 inches 19 13 16 23 3 4 38 9 16 6 3 16 10 3 15 16 4 1 2 1 9 16 1 1 2 NPT 1 1 2 NPT 6mm 230 1 60 V ph Hz Power supply Alimentation Air flow Circulation de l air Cod...

Page 29: ...511 38457511 38457511 38457511 38457511 38457511 38457511 38457511 38457511 1S1 Main power switch 38457826 38457826 38457826 1V1 Complete solenoid drain valve 38457537 38457537 38457537 38457537 38457...

Page 30: ...457511 1S1 Main power switch 38459657 38459657 1V1 Complete solenoid drain valve 38459665 38459665 1B1 Drain solenoid valve coil 38459673 38459673 CND Condenser 38459681 38459699 FF Filter dryer 38459...