18
Figure 15. View Logged Data Screen
In order to scroll through the data, which is set to a default of recording every 60 minutes, the operator can
press:
Moves to the next logged event.
Moves to the previous logged event.
When finished viewing the logged data, the operator can then press <ESC> to return Run Mode.
Ozone Sensor Operation
The ozone sensor must be operational for the system to work. If it is damaged, or a failure occurs, the PLC
will shut down the purification chamber.
The sensor is sensitive to water and depends upon good airflow. The sensor was installed by the Ingersoll
Rand EMS Certified Technician to provide the best measurement results and where airflow will not be
blocked. Once installed, the sensor should not be moved.
For best results, ensure there is nothing placed in the vicinity of the sensor that would block airflow to the
sensor or create excessive air turbulence around the sensor. This would cause the speed of the internal fan to
fluctuate and could cause sensor failure.
The Ingersoll Rand EMS Certified Technician will install the proper sensor for the room type (controlled
atmosphere/low oxygen head vs. standard head). If the room application changes please contact the
Ingersoll Rand EMS Certified Technician, as a different sensor head may be required.