A.
Insert key and rotate clockwise approximately 60 degrees.
B.
Depress lever retainer with tool provided.
C.
Slide lever off spindle.
TO RE-INSTALL LEVER
D.
Insert cylinder into spindle.
E.
Slide lever onto spindle.
F.
Insert key into cylinder and rotate clockwise approximately 60 degrees
and push lever over retainer.
G.
Give a pull on lever to be sure retainer engaged lever.
STEP 12
TO REMOVE STANDARD CYLINDER LEVERS
For proper function of the lock the right tailpiece must be used and must be
installed correctly. All RU-Series locks with standard cylinders must have the
tailpiece installed vertically on the cylinder as shown.
The cap must be properly adjusted. If too loose, excessive plug end play will
prevent the key from being withdrawn. If too tight, the plug will drag and be diffi-
cult to rotate with the key.
STEP 13
STANDARD CYLINDER TAILPIECE INSTALLATION
A.
If the cylinder & handle are installed, refer to step 12 for lever
removal instrucitons.
B.
Using a thin flat screw driver, turn the action bar slot clock-
wise (cw) until it stops at about 2:00.
C.
Then turn the action bar counterclockwise (ccw) to the 9:00
position.
There is no physical stop at this location.
D.
With the key out, install standard cylinder into the spindle.
E.
Refer to step 12 for lever installation instructions.
F.
Operate key to test for proper operation.
STEP 14
TIMING INSTRUCTIONS FOR STANDARD CYLINDER LOCKS
For The Following Functions: RU371, RU381, RU561, RU571
C
A
B
Cylinder
Spring
Pin
Tailpiece
Cap
RH Shown
Action
bar slot
Door
edge