Technical data sheet
MODEL
HC-3
HC-6
HC-7
HC-9
Flow (SCFM) @ 100 PSIG
100°F Drying Temperature
301 535 677 836
Vessel OD – Inches
12
16
18
20
Desiccant type
IR Activated Alumina
Lbs. Desiccant / Vessel
223
397
502
620
Inlet connection
2 NPT
2 NPT
3 FLG
3 FLG
Outlet connection
2 NPT
2 NPT
3 FLG
3 FLG
FILTER
•
Afterfilter AF-350
AF-550
AF-1000
AF-1000
Voltage
115/1/60 Standard -
Consult Factory for other voltages
Cooling Water GPM
9
16
20
25
Stripping Flow SCFM
6
11
14
17
Cycle time
8 Hour NEMA Cycle –
4 Hours drying/ 4 Hours Regeneration
Outlet Dewpoint
Variable
DPDS Control
Adjustable
High Humidity Alarm
Adjustable
Pressure Switch Setpoints
10 PSI Fail to Shift 60 PSI Initiate Cooling
Cooler outlet high
temperature alarm
105
°
F
Low regeneration
temperature alarm
Adjustable
Process flow
Downward Regeneration / Upward Drying