Book 43212455 (11/03)
17
PIPING
General
As CMH Series compressors are comprised of two modules (compressor and separator), there is
necessarily interconnecting piping between the two. These hoses are not provided with the units, as the
required lengths of the hoses are dependent on the relative location of the two modules in their installed
location. It is left to the installer to obtain hoses of the correct type and length for each installation.
The following hoses will be needed:
LOCATION SIZE HOSE
TYPE
Compressor Module to Oil Temp
Bypass Valve Outlet (Filter)
-12 JIC
Parker-Hannifin 213, or
Aeroquip FC350, or equivalent
Compressor Module to Hydraulic
Supply
-12 JIC
Parker-Hannifin 301 or equivalent
Compressor Module to Hydraulic
Return
-12 JIC
Parker-Hannifin 301 or equivalent
Compressor Module to Case
Drain Return
-6 JIC
Parker-Hannifin 213, or Aeroquip
FC350, or equivalent
Compressor Module to Separator
Scavenge
-4 JIC
Parker-Hannifin 213, or Aeroquip
FC350, or equivalent
Compressor Module to Air
Pressure Regulator Outlet
-6 JIC
Parker-Hannifin 213, or Aeroquip
FC350, or equivalent
Compressor Module to Separator
Discharge
-6 JIC
Parker-Hannifin 213, or Aeroquip
FC350, or equivalent
Compressor Module to Oil Cooler
Drain
-6 JIC
Parker-Hannifin 213, or Aeroquip
FC350, or equivalent
Oil Cooler to Oil Temp Bypass
Valve Port “B”
-24 JIC
Parker-Hannifin 206, or Aeroquip
FC300, or equivalent
Oil Cooler to Oil Temp Bypass
Valve Port “C”
-24 JIC
Parker-Hannifin 206, or Aeroquip
FC300, or equivalent
Airend Discharge to
Receiver/Separator Inlet
-32 JIC
Parker-Hannifin 206, or Aeroquip
FC300, or equivalent
NOTES:
1. All hoses terminate at marked bulkhead fittings on drive end of machine, except oil cooler
connections, which are on the cooler side of the compressor module.
2. All hoses terminate in Type I (SAE J516 female swivel straight), 37
°
JIC flare fittings on each end.
3. Ports “B” and “C” on oil temperature bypass valve can be connected to either port on the oil cooler.
Oil cooler performance is not sensitive to flow direction.
4. 2 inch NPT to –32 JIC adapter and fitting for airend discharge pipe is customer supplied.
Compressor Discharge Piping
The connection between the compressor package and the receiver separator must be furnished by the
customer. It is recommended the customer use a flexible line with an inside diameter of the same size, or
larger than the compressor package discharge connection. All piping must be certified safe for the
pressures and temperatures involved.