Temperature & Humidity Sensor
TH100NX Installer Guide
CONFIGURATION TABLE
Parameter Description
Length
(Bytes)
R/W
Default
Value
Valid Values
1
Time between Battery Reports (hours)
1
R/W
0
Range: 1
–127 hours
0 = Do not send periodically
2
Send BASIC SET ON above this temperature
(See #20)
1
R/W
121
Range: 15°
– 120° F
121 = Disabled
3
Send BASIC SET ON below this temperature
(See #20)
1
R/W
121
Range: 15°
– 120° F
121 = Disabled
4
Send BASIC SET OFF above this temperature
(See #20)
1
R/W
121
Range: 15°
– 120° F
121 = Disabled
5
Send BASIC SET OFF below this temperature
(See #20)
1
R/W
121
Range: 15°
– 120° F
121 = Disabled
6
Send multiple attempts for all BASIC SET
commands
1
R/W
0
1-5 = Number of extra attempts sent
every minute after first send
0 = Disabled
7
Temperature Units
1
R/W
1
1 = Fahrenheit
0 = Celsius
8
Association Group1
– Temperature delta auto
send threshold
1
R/W
10
Range: 1 - 200
Parameter is in tenths of degrees.
9
Association Group1
– Periodic temperature
send interval
1
R/W
0
Range: 1-120 minutes
0 = Disabled
10
Association Group2
– Temperature delta auto
send threshold
1
R/W
10
Range: 1 - 50
0 = Disabled
Parameter is in tenths of degrees.
11
Association Group2
– Periodic temperature
send interval
1
R/W
0
Range: 1-120 minutes
0 = Disabled
12
Send BASIC SET ON above this humidity
(See #20)
1
R/W
0
Range: 1
–100%
0 = Disabled
13
Send BASIC SET ON below this humidity
(See #20)
1
R/W
0
Range: 1-100%
0 = Disabled
14
Send BASIC SET OFF above this humidity
(See #20)
1
R/W
0
Range: 1-100%
0 = Disabled
15
Send BASIC SET OFF below this humidity
(See #20)
1
R/W
0
Range: 1-100%
0 = Disabled
16
Association Group1
– Humidity delta auto send
threshold
1
R/W
5
1-50%
17
Association Group1
– Periodic humidity send
interval
1
R/W
0
Range: 1-120 minutes
0 = Disabled
18
Association Group3
– Humidity delta auto send
threshold
1
R/W
5
Range: 1-30%
0 = Disabled
19
Association Group3
– Periodic humidity send
interval
1
R/W
0
Range: 1-120 minutes
0 = Disabled
20
BASIC SET options for temperature and
humidity
1
R/W
1
Configuration Register Combinations:
1 = Enable Registers 2, 5, 12 15
2 = Enable Registers 2, 5, 13, 14
3 = Enable Registers 3, 4, 12, 15
4 = Enable Registers 3, 4, 13, 14
21
Temperature Offset
1
R/W
0
Range: -7° to 7° F
22
Humidity Offset
1
R/W
0
Range: -7% to 7%
23
Humidity Filter Time Constant
1
R/W
30
Range: 1
– 60 minutes
© 2017 Ingersoll Rand
Rev. 20170629
These instructions are ONLY for connecting a Z-Wave wireless temper-
ature sensor to a new or existing Z-Wave network. This sensor
CANNOT be used as a remote temperature sensor for an 824, 850 or
1050 comfort control.
IMPORTANT: