2
WARNING SYMBOL IDENTIFICATION
Always wear eye protection
when operating or perform-
ing maintenance on this tool.
WARNING
WARNING
Always wear hearing
protection when operating
this tool.
Read this manual before
operating tool.
WARNING
LUBRICATION
•
90 psig maximum at tool inlet.
•
Lubrication -- Inject approximately 1.5 cc of
Powerforce No. 50 Oil into the air inlet before
starting the tool and after each two or three hours
of operation, unless the air line lubricator is used.
Lubricate with 1.5 cc of Powerforce No. 50 Oil
before storage.
INSTALLATION
(Dwg. TPD905--2)
F
L
R
Main Line(s) Inner Ø
to be 3X Size of
Air Tool’s Inlet Ø
To Air
System
To Air
Tool
Lubricator
Emergency
Shut--Off
Valve
Regulator
Filter
Compressor
FRL
Drain Regularly
Branch Line(s) Inner Ø
to be 2X Size of
Air Tool’s Inlet Ø
SPECIFICATIONS
Model
H
Sound Level
dB (A)
♦
Vibrations
Level
Inlet
Connection
Minimum
Inside Ø
Air Hose
Pressure
Power
m/s
2
Thread Type
Inches (mm)
PF900
91
104
5.2
1/4” NPT
1/4 (6.35)
H
Tested in accordance with PNEUROP PN8NTC1.2
♦
Tested in accordance with ISO8662--1
TROUBLESHOOTING
Low Power
Erratic Action
Blows Air /
Won’t Run
Too Noisy
Causes and Solutions
X
Check air pressure.
X
X
X
X
Check for water in lines.
X
X
X
X
Oil tool with air tool oil.