8
Eiger Fault Finding
’Power on’. L.E.D.
does Not
illuminate.
Control Voltage
not available
Control Circuit
Interrupted By a
Safety Circuit
Device
Control voltage
not available to
relay inputs
Check the control fuses.
Confirm Incoming Power is correct
voltage
Check the transformer secondary
windings for 24 VAC control
voltage and 110 VAC.
Check machine for indicated fault
and repair.
Attempt to ’reset’ the controller by
removing power to the controller
.
Check MCB3 for voltage, Controller
has no power to relay outputs.
This controller has no provision to
detect a power loss to the relay
outputs.
Reset controller
Insufficient Coolant
Circulation,
insufficient cooling.
Compressor trips
indicating a high
compressor
temperature.
Fault T 13, W 13
Check coolant level
Intellisys indicates
a tripped condition.
Compressor is
stopped but
Intellisys indicates
that it is still
running (STD
controller only)
Check Temperature sensors
Check thermostatic valve
AC, Check cooling air flow, cooler
restrictions, exhaust vents, inlet
restrictions.
WC, check water flow, strainer,
and water temperature
Excessively high ambient
Temperature / Humidity
(i.e. greater than 46C (115F).
Summary of Contents for R110IU-10
Page 5: ...5 S3 Intellisys Controller Operating Instructions...
Page 6: ...6 Software Navigation...
Page 7: ...7 Eiger Controller Fault Indicators 020 Tr Motor PTC Open High Motor Temperature...
Page 14: ...14 Star Delta Wiring Diagram...
Page 15: ...15...
Page 16: ...16 Soft Start Wiring Diagram...
Page 17: ...17...
Page 18: ...18 Line Start Schematic...
Page 19: ...19...
Page 20: ...20 Process and Instrumentation Diagram...
Page 21: ...21...
Page 28: ...28 Maintenance...
Page 29: ...29 Maintenance...
Page 30: ...30 Maintenance...
Page 31: ...31 S3 Controller Input Output Overview AI Analog Input DI Digital Input DO Digital Output...
Page 45: ...45 Standard S3 Menu Structure and Parameters Table 12...
Page 46: ...46 Standard S3 Menu Structure and Parameters Table 12...
Page 47: ...47 Standard S3 Menu Structure and Parameters Table 12...
Page 49: ...49 Modbus Register Listing...
Page 50: ...50 Table 13 Modbus Register Listing...
Page 52: ...52 Appendix 1 Thermistor 2ATT 34 to 124 C 255 F Air end Discharge...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57...
Page 58: ...58 General Specifications for Eiger Packages...
Page 59: ...59...
Page 60: ...60...
Page 61: ...61...
Page 62: ...62...
Page 63: ...63...
Page 64: ...64...
Page 65: ...65...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...
Page 73: ...73...
Page 74: ...74...
Page 75: ...75...
Page 76: ...76...
Page 77: ...77...
Page 78: ...78...
Page 79: ...79...