12
TAM7-SF-2E-EN
TAM7A0A24
AIRFLOW
PERFORMANCE
CONSTANT
CFM
MODE
/
CONSTANT
TORQUE
MODE
OUTDOOR
MUL
TIPLIER
(T
ONS)
COOLING
AIRFLOW
SET
TING
AIRFLOW
POWER
EXTERNAL
ST
A
TIC
PRESSURE
(Constant
CFM
/
Constant
T
orque)
HEA
TING
AIRFLOW
SET
TING
AIRFLOW
POWER
EXTERNAL
ST
A
TIC
PRESSURE
0.1
0.3
0.5
0.7
0.9
0.1
0.3
0.5
0.7
0.9
1.5
tons
360
CFM/ton
CFM
W
atts
542
/
652
38/
59
547
/
559
67
/
71
548
/
407
101
/
78
547
/
NA
137
/
NA
541
/
NA
175
/
NA
390
CFM/ton
CFM
W
atts
586
46
599
80
600
115
599
153
595
192
380
CFM/ton
CFM
W
atts
574
/
679
43
/
65
583
/
593
75
/
78
587
/
464
110
/
87
588
/
167
148
/
94
581
/
NA
185
/
NA
410
CFM/ton
CFM
W
atts
618
53
633
88
636
124
637
163
629
202
400
CFM/ton
CFM
W
atts
605
/
705
49
/
71
618
/
626
82
/
85
624
/513
119
/
96
625
/
325
158
/
101
618
/
NA
196
/
NA
430
CFM/ton
CFM
W
atts
650
59
665
96
669
134
672
174
660
212
420
CFM/ton
CFM
W
atts
636
/
731
55
/
78
651
/
658
90
/
93
659
/
556
128
/105
660
/
406
168
/
112
653
/
NA
207
/
NA
450
CFM/ton
CFM
W
atts
681
66
696
104
703
144
704
185
696
225
2
tons
†
360
CFM/ton
CFM
W
atts
723
/
809
75
/
101
743
/
746
115
/
118
754
/
666
158
/
133
756
/
563
201
/
144
748
/
428
242
/
153
390
CFM/ton
CFM
W
atts
780
94
800
137
809
182
811
227
802
268
380
CFM/ton
CFM
W
atts
761
/
843
86
/
113
782
/
784
128
/
131
793
/
710
172
/
146
796
/
617
216
/
159
788
/
500
259
/
168
410
CFM/ton
CFM
W
atts
818
106
838
151
848
198
851
244
842
287
400
†
CFM/ton
CFM
W
atts
799
/
877
97
/
125
820
/
821
141
/
144
832
/751
187
/
161
835
/
666
233
/
174
827
/
561
276
/
183
430
CFM/ton
CFM
W
atts
856
119
876
167
887
215
889
262
881
307
420
CFM/ton
CFM
W
atts
836
/
911
109
/
139
858
/
858
155
/
158
870
/
792
203
/
175
873
/
712
250
/
189
866
/
615
294
/
199
450
CFM/ton
CFM
W
atts
894
134
913
183
925
233
927
282
920
327
2.5
tons
360
CFM/ton
CFM
W
atts
892
/
979
130
/
168
914
/
930
179
/
189
927
/
869
229
/
207
930
/
796
278
/
222
923
/
796
324
/
222
390
CFM/ton
CFM
W
atts
964
164
986
218
997
271
1000
322
992
370
380
CFM/ton
CFM
W
atts
939
/
1024
149
/
190
962
/
976
201
/
211
974
/
918
253
/
230
978
/
849
304
/
244
971
/766
351
/
255
410
CFM/ton
CFM
W
atts
1013
188
1034
244
1045
299
1049
353
1040
400
400
CFM/ton
CFM
W
atts
986
/
1070
170
/
215
1009
/1023
225
/
236
1022
/
967
279
/
255
1026
/
901
332
/
270
1019
/
821
380
/
280
430
CFM/ton
CFM
W
atts
1063
214
1083
273
1095
331
1097
385
1089
434
420
CFM/ton
CFM
W
atts
1035
/1118
194
/
242
1058
/1072
251
/
264
1071
/1018
308
/
282
1074
/
953
362
/
297
1066
/
877
411
/
307
450
CFM/ton
CFM
W
atts
1114
243
1135
305
1145
365
1145
420
1135
469
3
tons
360
CFM/ton
CFM
W
atts
1065
/
1148
209
/
261
1088
/
1102
269
/
282
1101
/
1048
327
/
301
1103
/
985
382
/
315
1095
/
910
431
/
325
390
CFM/ton
CFM
W
atts
1160
272
1181
337
1190
397
1189
453
1157
486
380
CFM/ton
CFM
W
atts
1126
/1209
244
/
301
1149
/1164
307
/
322
1160
/
1111
367
/
341
1161
/
1050
423
/
355
1151
/
978
472
/
364
410
CFM/ton
CFM
W
atts
1225
317
1244
384
1249
444
1230
486
1146
477
400
CFM/ton
CFM
W
atts
1190
/1271
285
/
347
1211
/1227
350
/
368
1220
/1175
412
/
386
1218
/
1115
467
/
399
1164
/
1046
483
/
408
430
CFM/ton
CFM
W
atts
1291
368
1305
434
1298
486
1217
476
1135
468
420
CFM/ton
CFM
W
atts
1255
/1334
331
/
397
1273
/1289
397
/
418
1278
/1239
459
/
435
1237
/
1180
483
/
448
1151
/
1113
475
/
455
450
CFM/ton
CFM
W
atts
1355
422
1361
485
1285
475
1206
467
1124
460
•
†
F
actory
Setting
•
Status
LED
will
blink
once
per
100
CFM
requested.
In
torque
mode,
actual
airflow
may
be
lower
.
•
T
orque
mode
will
reduce
airflow
when
static
is
above
approximately
0.3"
water
column.
•
All
heating
modes
default
to
Constant
CFM.
•
Cooling
airflow
values
are
with
wet
coil,
no
filter
MINIMUM
HEATER
AIRFLOW
CFM
—
HEATER
MATRIX
MODEL
NO.
BA
YEV
AC04BK1AA
BA
YEV
AC04LG1AA
BA
YEV
AC05BK1AA
BA
YEV
AC05LG1AA
BA
YEV
AC08BK1AA
BA
YEV
AC08LG1AA
BA
YEV
AC10BK1AA
BA
YEV
AC10LG1AA
BA
YEV
AC10LG3AA
BA
YEVBC15LG3AA
BA
YEVBC15BK1AA
BA
YEVBC20BK1AA
T
AM7A0A24
638/713
638/900
675
(a)
/900
600/713
–
–
–
WITHOUT
HEA
T
PUMP
/
WITH
HP
—
SEE
AIR
HANDLER
NAMEPLA
TE
FOR
APPROVED
COMBINA
TIONS
Note:
Minimum
auxiliary
heating
airflow
is
automatically
configured
by
the
air
handler
model
and
the
auxiliary
heater
model
number.
This
is
not
field
adjustable.
(a)
Heater
not
qualified
for
208V
when
installed
in
horizontal
left
position
without
Heat
Pump