TAM7-SF-2E-EN
3
Product Specifications
MODEL
TAM7A0A24H21SD
TAM7A0A24H21EA
TAM7A0B30H21SD
TAM7A0B30H21EA
TAM7A0C36H31SD
TAM7A0C36H31EA
RATED VOLTS/PH/HZ.
200-230/1/60
200-230/1/60
200-230/1/60
RATINGS
(a)
See O.D. Specifications
See O.D. Specifications
See O.D. Specifications
INDOOR COIL — Type
Plate Fin
Plate Fin
Plate Fin
Rows — F.P.I.
3 - 14
3 - 14
3 - 14
Face Area (sq. ft.)
3.67
5.04
5.50
Tube Size (in.)
3/8
3/8
3/8
Refrigerant Control
EEV
EEV
EEV
Drain Conn. Size (in.)
(b)
3/4 NPT
3/4 NPT
3/4 NPT
DUCT CONNECTIONS
See Outline Drawing
See Outline Drawing
See Outline Drawing
INDOOR FAN — Type
Centrifugal
Centrifugal
Centrifugal
Diameter-Width (In.)
11 X 8
11 X 10
11 X 10
No. Used
1
1
1
Drive — No. Speeds
Direct - Variable
Direct - Variable
Direct - Variable
CFM vs. in. w.g.
See Fan Performance
Table
See Fan Performance
Table
See Fan Performance
Table
No. Motors — H.P.
1 - 1/2
1 - 1/2
1 - 1/2
Motor Speed RPM
Variable ECM
Variable ECM
Variable ECM
Volts/Ph/Hz
208-230/1/60
208-230/1/60
208-230/1/60
F.L. Amps
3.0
3.0
3.0
FILTER
Filter Furnished?
No
No
No
Type Recommended
Throwaway
Throwaway
Throwaway
No.-Size-Thickness
1 - 16 X 20 - 1 in.
1 - 20 X 20 - 1 in.
1 - 22 X 20 - 1 in.
REFRIGERANT
R-410A
R-410A
R-410A
Ref. Line Connections
Brazed
Brazed
Brazed
Coupling or Conn. Size-in. Gas
3/4
3/4
7/8
Coupling or Conn. Size-in. Liq.
3/8
3/8
3/8
DIMENSIONS
H x W x D
H x W x D
H x W x D
Crated (In.)
51.5 x 19.0 x 23.5
56.5 x 23 x 23.5
57.25 x 25.25 x 23.5
Uncrated
49.9 x 17.5 x 21.75
55.7 x 21.3 x 21.75
56.9 x 23.5 x 21.75
WEIGHT
Shipping (Lbs.)/Net (Lbs.)
127/116
150/138
157/146
(a)
These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps (AHRI STANDARD 210/240).
(b)
3/4” Male Plastic Pipe (Ref.:ASTM 1785–76)