18-GJ83D1-1C-EN
45
Table 22.
CDA Config Menu
CONFIG MENU ↕
↔
AIRFLOW MODE ↔↕
CFM* CFM*
AIRFLOW MODE ↔
TRQ CFM*
COOL CFM/TON ↔↕
XXX* XXX
HEAT CFM/TON ↔↕
XXX* XXX
EXT SW CL ↔↕
IGNORE*
IGNORE
EXT SW CL ↔
DS-ALL IGNORE
EXT SW CL ↔
DS-CLG IGNORE
EXT SW HT ↔↕
IGNORE* IGNORE
EXT SW HT ↔
DS-ALL IGNORE
EXT SW HT ↔
DS-HTG IGNORE
ALERT
m
e
n
u
CONTROL
menu
RESTORE
DFLT? ↕
NO (
Y
ES)
<ENTER>
ARE YOU SURE?
NO (YES)
<ENTER>
Note:
“
“
denotes
active
value
“*” indicates factory value
ID HEAT TY
PE ↔↕
EH* EH
ID HEAT TYPE ↔
HH EH
EH CFG #PH ↔↕
XX* XX
EHC AIRFLOW ↔↕
LOW* LOW
EHC AIRFLOW ↔↕
MED* LOW
EHC AIRFLOW ↔↕
HI* LOW
OD UNIT TYPE ↔↕
1-1* 1-1
OD UNIT TYPE ↔↕
2-1* 1-1
OD UNIT TYPE ↔↕
2-2* 1-1
OD TYPE ↔↕
HP* HP
OD TYPE ↔↕
AC* HP
OD TONNAGE ↔↕
XX*
CONT FAN MULT ↔↕
XX*
CL DLY PR ↔↕
CLPR X*
HT DLY PR ↔↕
HPPR X*
Note: Wiring to the External Switch inputs must be a normally
closed circuit with no power applied.
Note: Disable cool (DS-CLG) and disable all (DS-ALL) will
generate an error on the thermostat.
•
Coo
lin
g
&
Heating CFM
per ton
options are
from
290
through
450 in 10 CFM
increments.
•
The CFM per ton setting must be at 400 when
Zoning or a Variable Speed OD unit is installed
•
This configuration op
tion for the 08 or 011 hydronic
coil
is only available for the 5 ton TAM9 unit.
2-4 ton units do not have this configuration
option available.
Select heater size
- See EH menu (electric heater)
EH menu (electric heater) options
PARK (default)
◦ 4K
◦ 5K
◦ 8K
◦ 10K
◦ 15K
◦ 20K
◦ 25K
Heater size availability is based
on unit size for this menu.
•
The OD unit type must be configured for 24 volt systems only
o
1-1 is a single stage single compressor OD unit
o
2-1 is a two stage single compressor OD unit
o
2-2 is a dual stage dual compressor OD unit
•
Continuous
fan can be set between 35 & 100%
in 5% increments
•
The External Switch is to be configured independently for
heating and cooling modes of operation.
o
DS-CLG will disable compressor operation in cooling mode
o
DS-HTG will disable indoor heat in heating mode
o
DS-ALL will disable all operation in per the mode selected
•
The Airflow Mode has an option for CFM or To
rque. Torque
is recommended for high static conditions. Torque mode will
deliver reduced air flow with lower blower watts in high static
conditions. CFM is required when zoning or a variable speed
outdoor unit is applied. Evaluate the blower performance tables
in relation to the duct design when selecting this configuration option.
•
The
blower delay profile is to be configured for heating and
cooling modes of operation. There are 4 blower off delay
options:
o
Option 1 = 90 seconds at 100% air flow
o
Option 2 = No Delay
o
Option 3 = 180 seconds at 50% air flow
o
Option 4 = Enhanced Mode
OFF
OFF
50%
80%
100% if necessary
50%
Dehumidify
Warm Air Heating
Fast Coil Cooling
Fast Coil Heating
Efficiency
7.5
minutes
3
minutes
1
minute
F
A
N
O
P
E
R
A
T
IO
N
(
C
F
M
)
as required
COMPRESSOR OPERATION ON
OFF