background image

FOREWORD

2

UP6RD–5–175, UP6RM–5–175, UP6RD–5–175

The contents of this manual are considered to be proprietary and

confidential to Ingersoll–Rand and should not be reproduced without
the prior written permission of Ingersoll–Rand.

Nothing contained in this document is intended to extend any

promise, warranty or representation, expressed or implied, regarding
the Ingersoll–Rand products described herein. Any such warranties or
other terms and conditions of sale of products shall be in accordance
with the standard terms and conditions of sale for such products, which
are available upon request.

This manual contains instructions and technical data to cover all

routine operation and scheduled maintenance tasks by operation and
maintenance staff. Major overhauls are outside the scope of this
manual and should be referred to an authorized Ingersoll–Rand service
department.

All components, accessories, pipes and connectors added to the

compressed air system should be:
.

of good quality, procured from a reputable manufacturer and,

wherever possible, be of a type approved by Ingersoll–Rand.
.

clearly rated for a pressure at least equal to the machine maximum

allowable working pressure.
.

compatible with the compressor lubricant/coolant.

.

accompanied with instructions for safe installation, operation and

maintenance.

Details of approved equipment are available from Ingersoll–Rand
Service departments.

The use of non–genuine spare repair parts other than those

included within the Ingersoll–Rand approved parts list may create
hazardous conditions over which Ingersoll–Rand has no control.
Therefore Ingersoll–Rand cannot be held responsible for equipment in
which non–approved repair parts are installed. Standard warranty
conditions may be affected.

Ingersoll–Rand reserves the right to make changes and

improvements to products without notice and without incurring any
obligation to make such changes or add such improvements to
products sold previously.

The intended uses of this machine are outlined below and examples

of unapproved usage are also given, however Ingersoll–Rand cannot
anticipate every application or work situation that may arise.

IF IN DOUBT CONSULT SUPERVISION

.

This machine has been designed and supplied for use only in the
following specified conditions and applications:
.

Compression of normal ambient air containing no known or

detectable additional gases, vapors. or particles
.

Operation within the ambient temperature range specified in the

GENERAL INFORMATION section of this manual.

The use of the machine in any of the situation types listed in

table 1:–
a) Is not approved by Ingersoll–Rand,
b) May impair the safety of users and other persons, and
c) May prejudice any claims made against Ingersoll–Rand.

TABLE 1

Use of the machine to produce compressed air for:

a) direct human consumption
b) indirect human consumption, without suitable filtration and purity
checks.

Use of the machine outside the ambient temperature range

specified in the GENERAL INFORMATION SECTION of this manual.

Use of the machine where there is any actual or foreseeable risk of

hazardous levels of flammable gases or vapors

Use of the machine fitted with non Ingersoll–Rand approved

components.

Use of the machine with safety or control components missing or

disabled.

The company accepts no responsibility for errors in translation of

this manual from the original English version.

ALL SEASON SELECT is a registered trademark of
Ingersoll–Rand Company USA.

COPYRIGHT 2003

INGERSOLL–RAND COMPANY

Summary of Contents for UP6RD-5-175

Page 1: ...ATE APRIL 2003 UP6RD 5 175 UP6RM 5 175 UP6RX 5 175 ENCLOSED 60Hz OPERATION AND MAINTENANCE MANUAL This manual contains important safety information and must be made available to personnel who operate...

Page 2: ......

Page 3: ...IATIONS SYMBOLS Contact Ingersoll Rand for serial number Up to Serial No From Serial No Not illustrated Option NR Not required AR As required SM Sitemaster Sitepack HA High ambient machine WC Watercoo...

Page 4: ...ipment in which non approved repair parts are installed Standard warranty conditions may be affected Ingersoll Rand reserves the right to make changes and improvements to products without notice and w...

Page 5: ...rs which can result in serious injury Never operate the compressor near flammable liquids or vapors If used to spray flammable materials keep compressor at least 20ft away from the spray area HIGH PRE...

Page 6: ...CK OIL DECAL 5 32263832 1 ROTATING FAN DECAL 6 22075618 1 SHIPPING TAG 7 56276652 1 HOT SURFACE DECAL 8 1 MOTOR LABEL 9 30286686 1 ROTATION ARROW DECAL ON TOP OF MOTOR 10 1 PARTS LABEL 11 32341075 1 S...

Page 7: ...DECAL 6 22075618 1 SHIPPING TAG 7 56276652 1 HOT SURFACE DECAL 8 1 MOTOR LABEL 9 30286686 1 ROTATION ARROW DECAL ON TOP OF MOTOR 10 1 PARTS LABEL 11 32341075 1 SAFETY LABEL 12 54499306 1 IR LOGO 13 3...

Page 8: ...one common downstream plant effective isolation valves must be fitted and controlled by work procedures so that one machine cannot accidently be pressurized over pressurized by another Compressed air...

Page 9: ...SON SELECT can be fed directly into a drainage system that has downstream sewerage treatment As waste water regulations vary by country and region it is the responsibility of the user to establish the...

Page 10: ...ONLY WHEN SWITCH IS MOUNTED UNDER PRESSURE AND VOLTAGE FREE 5 THIS SCHEMATIC APPLIES TO UNITS USING A COMBINATION PRESSURE SWITCH Three Phase Wiring CONTROL PANEL OPTIONS COIL POWER SUPPLY OPTION 1 TO...

Page 11: ...GENERAL INFORMATION 9 UP6RD 5 175 UP6RM 5 175 UP6RD 5 175 Three phase combination pressure switch Mains Motor 2 Nm Tightening torque Single phase combination pressure switch Mains Motor...

Page 12: ...INSTALLATION HANDLING 10 UP6RD 5 175 UP6RM 5 175 UP6RD 5 175 TYPICAL BASEPLATE MOUNTED COMPRESSOR mm Inches A 784 30 9 B 819 32 2 C 594 23 39 D E 335 13 19 F 614 24 2 G 12 0 472...

Page 13: ...TALLATION HANDLING 11 UP6RD 5 175 UP6RM 5 175 UP6RD 5 175 TYPICAL VERTICAL TANK MOUNTED COMPRESSOR mm Inches A 1769 69 7 B 813 32 01 C 404 15 91 D 649 25 6 E 404 15 91 F 678 26 7 G 14 2 x 22 0 56 x 0...

Page 14: ...is available for unloading and moving the compressor to the installation site NOTE Lifting equipment must be properly rated for the weight of the compressor CAUTION Lift the compressor by the shipping...

Page 15: ...nts DO NOT RUN THE COMPRESSOR WITHOUT REMOVING THE SHIPPING BLOCKS AND SHIPPING SCREWS A Shipping screws both ends 2 B Wooden shipping blocks 2 LOCATION IN THE PLANT WARNING FOR COMPRESSORS EQUIPPED W...

Page 16: ...ls not included in the list contact your dealer Materials Compatibility List Suitable VitonR TeflonR Epoxy Glass Filled Oil Resistant Alkyd Fluorosilicone Fluorocarbon Polysulfide 2 Component Urethane...

Page 17: ...165 150 40 NOTE If you use a petroleum based compressor lubricant at start up and decide to convert to ALL SEASON SELECT lubricant later the compressor valves must be thoroughly decarbonized and the...

Page 18: ...ting temperature S _C 0 40 S _F 32 104 Compressor RPM 1475 MOTOR Nominal power 5HP 3 7kW Speed RPM 3450 Enclosure NEMA1 Insulation class F Amps See spec label Starts per hour 6 GENERAL DATA Oil Sump c...

Page 19: ...e valve fully The air receiver will fill to cut out pressure and the motor will stop The unit is now ready for use NORMAL START UP 1 Set the pressure switch lever or control panel knob to OFF 2 Close...

Page 20: ...crewing the four screws holding the control panel The pressure switch cover can be removed by unscrewing the two screws holding the cover Pressure switch adjustment The compressor package will cut in...

Page 21: ...all pressure is vented from the system and that the machine cannot be started accidentally Ensure that maintenance personnel are adequately trained competent and have read the Maintenance Manuals Prio...

Page 22: ...d sheave are aligned and belt tension is satisfactory after installing new belts or tensioning existing belts FILTER REPLACEMENT 1 Unscrew and remove the wing nut securing the filter housing to its ba...

Page 23: ...d clean it Remove any debris that may be in the strainer body before replacing the filter screen 5 Replace plug and tighten with wrench 6 When putting the Electric Drain Valve back into service press...

Page 24: ...motor pulley crankshaft drive belt tension and alignment Repair or replace as required 2 Drain existing lubricant and refill with proper lubricant 3 Check line voltage and upgrade lines as required Co...

Page 25: ...er with 180 grit flex hone Knocking or rattling 1 Loose beltwheel or motor pulley excessive end play in motor shaft or loose drive belts 2 Compressor valves leaky broken carbonized or loose 3 Carbon b...

Page 26: ...or electric service panel too small 3 Poor contact on motor terminals or starter connections 4 Improper starter overload heaters 5 Bad motor 1 Check line voltage and upgrade lines as required Contact...

Reviews: