6. 

WARRANTY, OPERATING CONDITIONS 

 

For the instrument the manufacturer provides a warranty of two years from the delivery to the 

customer. The instrument may be used only in the manner described in this manual. The producer is 
not liable for damages resulting for failure to comply with the conditions set in this manual. 
 

The instrument is designed for an ambient temperature 15 - 35 °C; with humidity up to 80% 

without acid and caustic vapors. The inlet cord plugs into a socket circuit featuring protection 16 A. 
 

All  warranty  and  post  warranty  repairs  are  to  be  performed  by  the  manufacturer,  or  its 

authorized body. 
 
Warning!  

For using water as coolant, set in mode F2 lower limit of the temperature at 1°C and above. 

7. 

WASTE DISPOSAL 

At the end of life discard the instrument according to valid regulations on waste or return to 

the vendor or producer for liquidation. 

    
The instrument contains a cooling gas R 290. 
The instrument is destroyed as electronic waste.  

8. 

CONTENT 

 

1.

 

INTRODUCTION ...................................................................................................................... 2

 

2.

 

DESCRIPTION AND SPECIFICATION .................................................................................. 2

 

2.1

 

Description .............................................................................................................................. 2

 

2.2

 

Specification ............................................................................................................................ 3

 

3.

 

COMMISSIONING .................................................................................................................... 3

 

3.1

 

Unpacking ............................................................................................................................... 3

 

3.1.1

 

What you will need .......................................................................................................... 3

 

3.1.2

 

Connecting elements, instrument assembly ..................................................................... 4

 

3.2

 

Temperature controller ............................................................................................................ 4

 

3.3

 

Switching on the instrument .................................................................................................... 5

 

4.

 

ROUTINE MAINTENANCE AND SERVICE ......................................................................... 6

 

5.

 

ACCESSORIES .......................................................................................................................... 6

 

6.

 

WARRANTY, OPERATING CONDITIONS ........................................................................... 7

 

7.

 

WASTE DISPOSAL ................................................................................................................... 7

 

8.

 

CONTENT .................................................................................................................................. 7

 

 

Summary of Contents for COR 400

Page 1: ...rvice INGOS Ltd K Nouzovu 2090 143 00 Prague 4 Czech Republic Tel 420 225 983 400 420 225 983 409 Fax 420 244 403 051 e mail instruments ingos cz www ingos cz 17 7 2019 CIRCULATION CHILLER COR 400 Use...

Page 2: ...Chiller Warning Using devices other than as described in the instructions can cause security breaches 2 DESCRIPTION AND SPECIFICATION 2 1 Description The instrument consists of a box in which is therm...

Page 3: ...ct all packing material If any item is missing contact the manufacturer or your supplier Place the instrument on the table and familiarize yourself with the distribution and function of the controls a...

Page 4: ...e coupling it is necessary to moisten the end 3 2 Temperature controller Display along with a button keyboard provide user comfort for direct control The function of the individual keys is as follows...

Page 5: ...or in 30 seconds the thermostat when there is no button operation will return to normal operating mode Setting item Range setting parameters Factory setting code Temperature difference 1 C 16 C 1 C F0...

Page 6: ...f paint on the instrument The surface of the instrument clean with a soft cloth Cleaning the condenser perform at least 1x per month by sweeping or air pressure or CO2 Fan cover by pulling upward pull...

Page 7: ...be performed by the manufacturer or its authorized body Warning For using water as coolant set in mode F2 lower limit of the temperature at 1 C and above 7 WASTE DISPOSAL At the end of life discard th...

Reviews: