21
IDS 805 User Manual 700-266-01C Issued March 2009
15. Troubleshooting
15.1 Trouble Conditions
In the event of a trouble condition the power indicator will flash. Trouble Condition refers to Low Battery
power and/or AC Mains Failure. Check that the plug is in place and switched on. If the power indicator is
still flashing once these checks have been done, contact your installer who will then check the battery
power.
15.1.1 Viewing Trouble Conditions
Hold down the [7] until the beep
If the POWER LED is flashing (or if so programmed, the keypad is beeping) hold down the
[7]
key for
one second. The ARMED, AWAY, and READY indicators will start flashing to show that the keypad is in
the TROUBLE viewing mode. Refer to the table below to find the significance of each lit zone LED. The
system will automatically exit the TROUBLE mode after ten seconds. To clear the trouble condition press
[#]
within 5 seconds of viewing. To simply cancel the beeping without viewing the trouble conditions,
press
[#]
.
Indicator
Trouble Condition
2
Failure to communicate to monitoring company
3
Mains power failure
4
Low battery
5
The Telephone line has been cut or is not present
6
The siren wire has been cut or the fuse has blown
7
Keypad has experienced a tamper
8
Installers code must be entered to clear an alarm condition
15.2 Problems when Arming the System
If you enter the wrong user code, the keypad will beep three times and the system will not arm.
Is the READY Indicator on?
If this indicator is not on, one or more zones are violated. A flashing zone indicator shows a violation.
Ensure that all monitored doors and windows are closed. Bypassing a violated zone will also create a
READY condition.
Does the siren sound before you exit?
The exit delay may be too short - ask your installer to adjust the exit delay.
OR
You have not left via a Follower and Entry/Exit zone or have strayed into an Instant zone. Either avoid
these zones or ask your installer to change the zone type.
Summary of Contents for IDS 805
Page 1: ......
Page 2: ...2 IDS 805 User Manual 700 266 01C Issued March 2009...
Page 5: ...5 IDS 805 User Manual 700 266 01C Issued March 2009...
Page 6: ...6 IDS 805 User Manual 700 266 01C Issued March 2009...
Page 25: ...25 IDS 805 User Manual 700 266 01C Issued March 2009...
Page 26: ...26 IDS 805 User Manual 700 266 01C Issued March 2009...
Page 28: ...28 IDS 805 User Manual 700 266 01C Issued March 2009...