IDS 805 User Manual   700-266-01C   Issued March 2009 

Glossary 

 

Alarm Memory

  

 

This is the history of the most recent violations that occurred the last time the system was armed. 

Arm

 

 

To set the system into the ARMED mode. In this mode, violating a zone will activate an alarm condition. If 

the system is programmed accordingly, it will cause a reporting code to be sent to the monitoring 

company. 

Bypass 

      

 

To deactivate a zone. When the panel is ARMED, violation of a bypassed zone will be ignored. 

Disarm 

      

 

To deactivate the system. Fire, medical and panic functions remain active while the system is disarmed. 

 

Entry/Exit Zone

  

 

A zone with a programmable time delay, which allows the user to exit the premises after arming the 

system and time to get to the keypad after entering the armed premises. This zone is generally the last 

exit point of the building and the first entry point i.e. the front door of a home. 

 

Follower Zone  

     

A zone that may be temporarily violated during the exit delay period or after violation of an Entry/Exit 

zone. This allows the user access to disarm the system. A Follower zone will behave as per an Instant 

zone if violated prior to the violation of an Entry/Exit zone. 

 

Instant Zone    

      

When the system is armed, violation of an Instant zone will immediately cause an alarm condition to be 

registered. 

Stay Arm

    

 

Arming that allows for certain preprogrammed, STAY zones to be violated while the system is armed. 

 

Stay Arm

 

and Go

 

Arming that allows the user to STAY ARM and leave the premises. 

Stay Zone

   

 

Zones which are bypassed automatically when the system is STAY ARMED. 

Zone

 

 

A specific area of your premises guarded by sensors which detect violations of that area. 

 
 
 
 
 
 
 
 

Summary of Contents for IDS 805

Page 1: ......

Page 2: ...2 IDS 805 User Manual 700 266 01C Issued March 2009...

Page 3: ...13 5 6 Arming from a Key switch or Remote Control 13 5 7 Auto Arming 13 5 8 Arming with Entry Exit or Follower Zones Violated 13 5 9 Forced Arming 14 6 Zone Bypassing 14 6 1 To Bypass a Zone 14 6 2 To...

Page 4: ...3 Buzz Zones 19 13 1 To Program Buzz Zones 19 13 2 ToCancel Buzz Zones 20 14 Chime Zones 20 14 1 To Program the Chime Zones 20 14 2 To Cancel the Chime Zones 20 15 Troubleshooting 21 15 1 Trouble Cond...

Page 5: ...5 IDS 805 User Manual 700 266 01C Issued March 2009...

Page 6: ...6 IDS 805 User Manual 700 266 01C Issued March 2009...

Page 7: ...to the keypad after entering the armed premises This zone is generally the last exit point of the building and the first entry point i e the front door of a home Follower Zone A zone that may be temp...

Page 8: ...and serviced by a qualified security professional who should instruct you regarding the level of protection provided and the operation of the system Should you have any questions regarding the operati...

Page 9: ...unted in a convenient location within the protected premises generally close to the Entry Exit zones After a preprogrammed period of inactivity the keypad will automatically enter into a power save mo...

Page 10: ...lated Stay Arm Stay Arm and Go Forced Arming Push to Arm Siren Sound on Arm Disarm single toot arm double2 toot disarm Panic Alarm Fire Alarm Chime Zones Buzz Zones Zone Tamper Monitoring Arm with Key...

Page 11: ...nt door 3 Press the key to cancel any unintended key entries 4 Enter a valid 4 digit USER CODE If you make a mistake press the key and re enter the code 5 The ARMED indicator will come on and the keyp...

Page 12: ...is selected the system will use the selected profile each time the system is armed into the STAY MODE If the alternate profile is required it is necessary to select the alternate profile before the s...

Page 13: ...or Remote Control Single toot on Arm Double toot on Disarm 1 Ensure that the READY indicator is on before leaving 2 Leave and close the door remembering to lock 3 Press the remote button or twist and...

Page 14: ...the key while bypassing zones violated zones will be flashing 2 Press the number corresponding to the zone you need to bypass e g the 2 key if you wish to bypass zone 2 3 The relevant zone indicator w...

Page 15: ...te Control 1 Press the remote button or twist and release the key switch 2 The system will disarm and the remote indicator if installed will turn off 3 If programmed to do so the siren will sound brie...

Page 16: ...is advisable to choose a code that can be easily remembered by all family or staff members 9 Emergency Evacuation Plan An emergency evacuation plan should be established in case of a fire Draw up a fl...

Page 17: ...s occurred To Display Zone Tamper Memory 0 then 2 1 Hold down 0 until the keypad buzzer sounds 2 The READY indicator will turn off and the keypad buzzer will sound briefly 3 Flashing zone indicators s...

Page 18: ...Monday arming the system on a Monday morning using the maid s code will allow the maid to disarm the system On days that any other user code i e not a maid s code has been used to arm the system enter...

Page 19: ...cause the keypad buzzer to sound for a period of 30 seconds during which time a valid user code must be entered If a valid user code is not entered during this period the system will register an alar...

Page 20: ...ers or exits the front door the keypad will beep each time the door is opened if that zone is programmed as a chime zone 14 1 To Program the Chime Zones 2 ZONE NUMBER 1 Hold down the 2 key until the k...

Page 21: ...ress within 5 seconds of viewing To simply cancel the beeping without viewing the trouble conditions press Indicator Trouble Condition 2 Failure to communicate to monitoring company 3 Mains power fail...

Page 22: ...e strayed into an Instant zone Does the siren sound before you get to the keypad You have strayed into a non follower zone OR You have taken too long to get to the keypad The panel will not disarm You...

Page 23: ...g13 B Battery 8 21 Buzz Zone 10 12 18 19 20 Bypass 7 9 11 12 13 14 16 17 18 21 27 C Control Panel 8 16 Chime 8 9 10 20 27 D Disarm 7 8 10 13 14 15 16 18 20 22 27 Duress 10 16 17 27 E Emergency Evacuat...

Page 24: ...see Arm Quick Stay Arm Go see Arm R Remote Control see Key switch Reporting Code 7 S Siren 10 13 15 16 20 21 22 Stay Arm see Arm Stay Arm Go see Arm Stay Mode 8 12 18 Stay Profile 12 27 Strobe 15 T Ta...

Page 25: ...25 IDS 805 User Manual 700 266 01C Issued March 2009...

Page 26: ...26 IDS 805 User Manual 700 266 01C Issued March 2009...

Page 27: ...ld down P for 1 second Fire Hold down F for 1 second Medical Emergency Hold down M for 1 second Alarm Memory Hold down 0 for 1 second Change Stay Profile MODE 9 PROFILE NUMBER Bypass a zone ZONE NUMBE...

Page 28: ...28 IDS 805 User Manual 700 266 01C Issued March 2009...

Reviews: