background image

Guide to networking

General information

5

Chapter 1

General information

1.1

Manufacturer's details

Manufacturer:  

INIM ELECTRONICS s.r.l

Production plant:  

Centobuchi, via Dei Lavoratori 10

Comune:  

63076, Monteprandone (AP) - Italy

Tel.:  

+39 0735 705007

Fax:  

+39 0735 704912

E-mail:  

info@inim.biz

Web:  

www.inim.biz

The persons authorized by the manufacturer to repair or replace the parts of this system, hold authorization to work on
INIM Electronics brand devices only.

1.2

About this manual

Manual code:  

DCMNINE0PRAESIDIA

Version:  

100

This manual describes the procedures for the configuration, commissioning and maintenance of the Praesidia fire-
detection system.

1.2.1 Terminology

Control panel, System, Device:  

The main supervisory unit or any constituent part of the fire detection system.

Left, Right, Behind, Above, Below:  

Directions as seen by the operator when directly in front of the mounted device.

Qualified personnel:  

Persons whose training, expertise and knowledge of the products and laws regarding security

systems, are able to create, in accordance with the requirements of the purchaser, the most suitable solution for the
protected premises.

Select:  

Click on a specific item on the interface (drop-down menu, options box, graphic object, etc.).

Press:  

Push a button/key or tap on a video button on a touchscreen or display.

1.2.2 Graphic conventions

Following are the graphic conventions used in this manual.

Note:

The notes contain important information relating to the text.

Conventions

Example

Description

Text in Italics

Refer to 

paragraph 

1.2.2 Graphic 

conventions

Directs you to the title of a chapter, section, 

paragraph, table or figure in this manual or 

other published reference.

<text>

<AccountCode>

Editable field

[Uppercase letter] or 

[number]

[A] or [1]

Reference relating to a part of the system 

or video object.

Summary of Contents for Praesidia series

Page 1: ...Guide to networking 1 FIRE DETECTION AND EXTINGUISHANT SYSTEM EN 54 2 EN 54 4 EN 54 21 EN 12094 1 0832 0832 CPR F1342 cert N 991K GUIDE TO NETWORKING...

Page 2: ...en goods or claims by any other party caused by defective products or otherwise arising from the incorrect or otherwise improper installation or use of this product This warranty applies only to defec...

Page 3: ...3 2 Use of optic fiber connections 8 3 3 Supervision of the Hornet network 8 3 4 Commissioning of a Hornet network 8 3 5 Sharing the events on the Hornet network 10 3 6 Activation of groups of outputs...

Page 4: ...4 Table of contents Fire detection and extinguishant system...

Page 5: ...ve Below Directions as seen by the operator when directly in front of the mounted device Qualified personnel Persons whose training expertise and knowledge of the products and laws regarding security...

Page 6: ...various nodes the supervision of the entire network by connecting to a single node it is possible to supervise the entire network by means of the appropriate supervision software e g supervisory softw...

Page 7: ...imum length 1000m between two successive control panels Compliant with local laws and regulations in force The connection must be a loop connection and must respect the direction of the wiring the ter...

Page 8: ...he IFMNET module all the other nodes in the network will signal the fault 3 4 Commissioning of a Hornet network Once several control panels have been connected in a Hornet network as indicated in the...

Page 9: ...he network As soon as a Hornet address is assigned the IFMNET module activates the blue LED to indicate that the control panel is in the cluster and has started to communicate with the other control p...

Page 10: ...ine which events from other control panels are to be displayed for each node of the Hornet network by duly configuring the Events filter section This section can be reached by selecting a control pane...

Page 11: ...ated in the parameters section of the selected group B the group will be the same for all the control panels in Hornet network The outputs associated with the group will activate regardless of control...

Page 12: ...ifferent paths and to take all the necessary precautions to ensure that the Ethernet physical layer provides fully secure and redundant capabilities 4 3 Supervision of the TCP IP network Once the TCP...

Page 13: ...eration in order to communicate to each component in the network the existence of all the other elements 11 To set the programming of the entire installation click on the Write button This operation m...

Page 14: ...f the repeater is 0 To do this it is necessary to access the Programming section as indicated above then access the Configuration section The configuration process continues through the control pane p...

Page 15: ...P address for the repeater 11 In the same list first click on the cluster the repeater is associated with L and then on the relative control panel underneath M 12 In the column on the right in the row...

Page 16: ...nguishant system Centobuchi via Dei Lavoratori 10 63076 Monteprandone AP Italy Tel 39 0735 705007 _ Fax 39 0735 704912 info inim biz _ www inim biz ISO 9001 Quality Management certified by BSI with ce...

Reviews: