InisBofin Insert Roomheater
In addition to installation
instructions supplied, the
requirements of BS.8303 and
BS.6461 Parts 1&2; 1984 must be
fulfilled. Also all local
authority bylaws and domestic
building regulations including
those referring to national and
European Standards regarding the
installation of solid fuelled
burning appliances, flues and
chimneys must be followed.
This stove is designed only to be
installed in a fireplace with a
chimney.
Stove preparation
The crate should be carefully
unscrewed to avoid possible damage
to the stove. The stove hand tool
should be taped to the top of the
stove along with this manual.
Remove the plastic packaging. Use
a screw driver to remove the screw
holding the stove in place. The
wooden crating the stove was
shipped in can be cut up for fuel
in the stove. Take great care to
avoid damaging the damper
mechanism on the underside of the
stove when removing the stove from
its shipping crate and moving it
into position.
To help with fitting of the
stove, the stove door and facade
and baffle assembly should be
removed. The door is removed by
opening the door and lifting up
approx. 20mm until the hinges are
clear and lift away. Take great
care not to drop the door as it is
quite heavy and the door glass can
easily be broken. The facade is
removed (See Fig 6) by removing
the indicated split pin with the
use of a pliers, gently but firmly
lift the facade approx. 5mm by
holding towards the left and right
sides of the façade along the top
to avoid deforming the facade in
the middle.
Remove the baffle assembly as
shown in the user manual and
remove the firebar and ash pan.
With the baffle assembly removed
the flue collar can be removed
prior to fitting of the stove.
Chimney
Chimneys must satisfy standard EN
15287:2007. A draught test should
always be performed prior to the
fitting of the stove to ensure
that a proper draw in the chimney
is present (Min 10Pa constant). A
chimney height of at least 4m from
the top of the stove must be used.
The chimney diameter must be at
least 150mm. The chimney must be
in good condition, be cleaned and
free from cracks and blockages.
The chimney must not have too
great a cross sectional area
(250mm Diameter) and if it has