the chimney should be lined with a
suitable flue liner for wood logs.
All chimneys and flues used must
be sealed for the best possible
performance. The draught in the
chimney must be at least 10
Pa when warm and must not suffer
from down draughts and if there is
an excessive draught in the
chimney a draught stabiliser
should be fitted. If any doubt
exists please contact a chimney
expert. If it is an existing
chimney that has been is use with
an open fire, the chimney must be
thoroughly cleaned and inspected.
Two to three weeks after the stove
has been in use, have the chimney
cleaned again as soot previously
secure may come loose as the flue
gas from the stove is quite
different than that from an open
fire.
Hearth and Fire Surround
If the installer has any doubts as
to the positioning of the stove
and necessary fire proofing,
expert advice should be sought
before any work begins. The stove
must be placed onto a fire proof
hearth of at least 12mm in depth
that is flat and level. The stove
positioning and hearth size are
governed by building regulations
The Platform on which the insert
is mounted should be stable and
strong to hold the weight of
insert room heater.