background image

 

 

 

IHC-230 User Manual

 

Inkbird Tech. Co., Ltd.                                                                        www.ink-bird.com

 

 

 INCREASE key  

 Work 1 Socket: 

Temperature output. 

 Work 2 Socket: 

Humidity output. 

 

 

4. Key Operation Instruction 

4.1 Enquiry Set Point 

Under  running  mode,  short  press  the  INCREASE  “

”  key,  display  code  TS  and 

temperature  setting  value;  short  press  the  DECREASE  “

”  key,  display  code  HS  and 

humidity setting value. The screen will return to normal display without pressing any keys 
in 2 seconds. 

 

4.2 How to Set Parameters 

Under running mode, press and hold

  SET 

key for 3 seconds to enter parameters setting 

mode, 

window1

  displays  the  first  menu  code  “MD”,  while 

window2

  displays  according 

setting value. Press

 SET

 key to page down the menu then the code will display, press “

” 

” key to change the current parameter values.  

After  finished  settings,  press  and  hold  “

”  key  for  3  seconds  at  any  status  to 

save the parameter setting value and return to the normal displaying mode.

  

During  setting,  if  there  is  no  operation  for  20  seconds,  system  will  quit  the  menu 
automatically and return to the mode of normal displaying without saving the parameters 

modification. 

 

Summary of Contents for IHC-230

Page 1: ...served No part of this document may be reproduced without prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject to revision without notice Please contact Inkbird to ensure you have the latest version of this document ...

Page 2: ...ow to Set Parameters 6 4 3 Setup Flow Chart 7 5 Menu Instruction 8 5 1 Control Range Setting 9 5 2 Humidity Temperature Control HD HS DS HC TS DS 9 5 3 Alarm Limit Setting AH AL 9 5 4 Compressor Delay PT 9 5 5 Calibration CA 10 5 6 Display in Fahrenheit or Centigrade unit CF 10 6 Error Description 10 Sensor Fault Alarm 10 7 Technical Assistance and Warranty 11 7 1 Technical Assistance 11 7 2 Warra...

Page 3: ...oduct Doing so may occasionally result in electric shock fire or malfunction DO NOT use the product where subject to flammable or explosive gas Otherwise injury from explosion may occasionally occur DO NOT disassemble modify or repair the product or touch any of the internal parts Electric Shock fire or malfunction may occasionally occur If the output relays have been used over their life expectan...

Page 4: ...dity 12A 100 240VAC Temperature 12A 100 240VAC Input Power Cable Length 1 5m 5ft Output Power Cable Length 30cm 1ft Dimension Main Body 140x68x33mm 5 5x2 7x1 3 inch Socket US Version 85x42x24mm 3 3x1 7x1 0 inch Socket EU Version 135x54x40mm 5 3x2 1x1 6 inch Socket UK Version 140x51x27mm 5 5x2 0x1 0 inch Ambient Temperature 30 75 C 22 167 F Storage Temperature 30 75 C 22 167 F Humidity 20 85 No Con...

Page 5: ... Cooling and dehumidifying devices Alarm will be on when temperature or humidity exceeds high low alarm setting value 3 Keys Instruction Window 1 Temperature measuring Value or Setting Menu Code Window 2 Humidity Measuring Value or Setting value Temperature Indicator Lamp Work1 On Working Off Stop Working Flickering Delay Output Humidity Indicator Lamp Work2 On Working Off Stop Working Flickering ...

Page 6: ...ow to Set Parameters Under running mode press and hold SET key for 3 seconds to enter parameters setting mode window1 displays the first menu code MD while window2 displays according setting value Press SET key to page down the menu then the code will display press key to change the current parameter values After finished settings press and hold key for 3 seconds at any status to save the paramete...

Page 7: ...IHC 230 User Manual Inkbird Tech Co Ltd www ink bird com 7 4 3 Setup Flow Chart ...

Page 8: ...y Protected Delay Only for Dehumidifying 0 10Minute 0 5 3 CA Humidity Calibration Offset 15 15 RH 0 5 4 When MD T Temperature setting mode Symbol Code Function Setting Range Default Note HC Temperature Control Mode H Heating C Cooling H 5 1 TS Temperature Set Value 40 100 40 212 25 DS Temperature Control Differential 1 20 2 AH Temperature High Limit Alarm 40 100 40 212 100 5 2 AL Temperature Low L...

Page 9: ...midity temperature higher than AH the humidity temperature high alarm will be on when the measured humidity temperature lower than AL the humidity temperature low alarm will be on When alarm is on the display will be flashing between the measured value and alarm code with the BI BI BIII sound The alarm sound can be stopped by pressing any key but the status of alarm will be not change until the va...

Page 10: ... degree displaying can be selected as needed Default displaying is in Centigrade degree Please set CF to F to change the displaying in Fahrenheit degree if needed Attentions After CF value changed all the setting value will be recovered to factory settings 6 Error Description Sensor Fault Alarm when sensor is being in short circuit or open loop the controller will initiate sensor fault mode by sto...

Page 11: ...ondition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or part of the thermostat The original receipt is required for warranty purposes INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising ...

Reviews: