ITC-308 User Manual

 

Inkbird Tech. Co., Ltd.                                                                        www.ink-bird.com

 

 

1. Overview 

What is ITC-308? 

ITC-308  is  an  easy-to-use,  safe  and  reliable  dual  relay  output  temperature  controller.  It 

can be used as over-temperature protection and automatic temperature control system for 

various  electric  appliances  such  as  equipment  for  home-brew,  aquarium,  pet  breeding, 
incubation,  BBQ,  seedling  heat  mats,  oven  temperature  control,  terrestrial  heat  control, 

constant  temperature  cycle  of  heating  pump,  culture  fermentation,  accelerating 

germination, electric radiator, electric oven, etc. 
 

This product has plug-n-play design with dual relay, be able to connect with refrigeration 

and heating equipment easily to realize ideal temperature control. It’s equipped with dual 

LED  display,  and  offers  display  options  of  Centigrade  and  Fahrenheit,  enabling  more 
humanized  temperature  control.  With  large  output  power  1200W(110V)  /  2200W(220V), 

it’s suitable for most applications. 

 

ITC-308  is  designed  with  compressor  delay  protection  for  refrigeration,  high  and  low 
temperature alarm, and sensor fault alarm, which makes the temperature controller more 

safe and reliable. Functions such as temperature calibration, separately set differential for 

refrigeration and heating, enable more accurate temperature control. 
 

Main features 

 

 

Plug and play design, easy to use;  

 

Dual relay output, be able to connect with refrigeration and heating equipment at the 

same time; 

 

Support reading with Centigrade or Fahrenheit unit;  

 

Maximum output load: 1200W(110V) / 2200W(220V);  

 

Dual display window, be able to display measured temperature and set temperature at 

the same time; 

 

Temperature calibration; 

 

Compressor delay protection for refrigeration control; 

 

High and low temperature alarms are available; 

 

Over-temperature and sensor fault alarm; 

 

Heating/cooling  differential  function  could  be  set  separately  for  refrigeration  and 
heating to protect temperature controller from violent change. 

 

 

 
 

 

 
 

Summary of Contents for ITC-308

Page 1: ... No part of this document may be reproduced without prior written permission Disclaimer Inkbird has made every effort to ensure that the information contained in this document is accurate and complete however the contents of this document are subject to revision without notice Please contact Inkbird to ensure you have the latest version of this document ...

Page 2: ... to Set Parameters 6 4 3 Setup Flow Chart 7 5 Menu Instruction 7 5 1 Temperature Control Range Setting TS HD CD 8 5 2 Alarm High Low Limit Setting AH AL 8 5 3 Compressor Delay PT 9 5 4 Temperature Calibration CA 9 5 5 Display in Fahrenheit or Centigrade unit CF 9 6 Error Description 10 Sensor Fault Alarm 10 Over temperature Alarm 10 7 Technical Assistance and Warranty 11 7 1 Technical Assistance 1...

Page 3: ...th large output power 1200W 110V 2200W 220V it s suitable for most applications ITC 308 is designed with compressor delay protection for refrigeration high and low temperature alarm and sensor fault alarm which makes the temperature controller more safe and reliable Functions such as temperature calibration separately set differential for refrigeration and heating enable more accurate temperature ...

Page 4: ...zzer Alarm High and Low Temperature Alarm Sensor Type NTC sensor Including Sensor Length 2m 6 56ft Relay Contact Capacity Cooling 10A 100 240VAC Heating 10A 100 240VAC Input Power Cable Length 1 5m 5ft Output Power Cable Length 30cm 1ft Dimension Main Body 140x68x33mm 5 5x2 7x1 3 inch Socket US Version 85x42x24mm 3 3x1 7x1 0 inch Socket EU Version 135x54x40mm 5 3x2 1x1 6 inch Socket UK Version 140...

Page 5: ...kering the compressor is under delay protection Heating Indicator Lamp when the light is on start heating SET key press SET key for 3 seconds to enter menu for function setting During the setting process press SET key for 3 seconds to quit and save setting changes DECRESE key under running mode press DECRESE key to inquiry CD value under setting mode press DECRESE key to decrease value INCREASE ke...

Page 6: ...meters When the controller is working normally press SET key for over 3 seconds to enter parameters set up mode SET indicator lamp will on PV window displays the first menu code TS while SV window displays according setting value Press SET key to go to next menu and display according menu code press key or key to set current parameter value After setting done press SET key for 3 seconds at any tim...

Page 7: ...ction Setting range Default setting Remarks TS Temperature Set Value 50 99 9 25 5 1 HD Heating Differential Value 0 3 15 2 0 CD Cooling Differential Value 0 3 15 2 0 AH Alarm High Limit 50 99 9 90 5 2 AL Alarm Low Limit 50 99 9 40 PT Compressor Delay 0 10 minutes 3 minutes 5 3 CA Temperature Calibration 15 15 0 5 4 CF Display in Fahrenheit or Centigrade C 5 5 ...

Page 8: ...ion equipment is under compressor delay protection status When the measured temperature PV TS temperature set value the cool indicator lamp will off and the refrigeration relay stops working When the measured temperature PV TS temperature set value HD heating differential value system enter heating status the heat indicator lamp will on and heating relay starts to work when the measured temperatur...

Page 9: ...than preset delay the equipment won t start refrigeration until preset delay is satisfied Delay time will be calculated right after the moment refrigeration stops 5 4 Temperature Calibration CA When there is deviation between measured temperature and actual temperature use temperature calibration function to align the measured temperature and actual temperature The corrected temperature is equal t...

Page 10: ... be dismissed by pressing any key After faults solved the system will return to normal working mode Over temperature Alarm when measured temperature exceeds the measuring range less than 50 C 58 F or higher than 99 C 210 F the controller will initiate over temperature alarm mode and cancel all the actions The buzzer will alarm LED displays HL Buzzer alarm could be dismissed by pressing any key Whe...

Page 11: ...ondition by the original purchaser not transferable against defects caused by INKBIRD s workmanship or materials This warranty is limited to the repair or replacement at INKBIRD s discretion of all or part of the thermostat The original receipt is required for warranty purposes INKBIRD is not responsible for injury property damage or other consequential damages or damages of third parties arising ...

Reviews: