7-9-5 S
TEP
P
ASS
C
ALIBRATION
Because each media has different thickness, one media feed command will result in different actual media
feed lengths. If printed image has horizontal banding or when using new type of media, it is recommended to
do a media calibration.
When doing a media calibration, a test chart will be printed, you should check the test chart and input the value
of the best-aligned group number, and then the Printer Control Software can compute how much
compensation should be made when feeding this type of media.
Follow the steps below to do the calibration:
1. Select
Step Pass Calibration
from the
Adjust Menu
; the Step Calibration dialogue pops up, which shows
the step value.
This dialogue is for you to check the step value; click button Calibrate to do the calibration if you are not
satisfied with the value, and click OK if the value is acceptable.
2. Clicking button Calibrate pops up the Media Calibration dialogue. With the options in the dialogue, users can
print a test pattern and enter the calibration value read from the pattern.
INKCUPS NOW SERIES INKJET PRINTERS
XJET
All rights reserved by Inkcups Now Corporation
Rev: SC71112