Installation and Safety Instructions

For Models without a Power Switch:

The socket outlet shall be installed near the equipment and shall be accessible.

For Models with 110 / 220V Power Selector:

Caution:  Before applying power to this unit, the voltage selector must be set to the appropriate setting to match local A/C line
voltage.  Improper setting of the voltage selector may cause damage to the unit and create a potential fire hazard.

The voltage selector is a round switch located next to the A/C power input connector which looks
like this:

 

Using a straight slot screwdriver or small coin, rotate the selector to the correct position so that

the arrow lines up with 110 or 220 as appropriate for local power line voltage as indicated in the
chart below:

Local A/C Voltage

Voltage Selector Setting

110 ~ 120 VAC

110

220 ~ 240 VAC

220

For all Models:

No serviceable parts inside the unit.  Refer service to a qualified technician.

For Models with Internal or External Fuses:

For continued protection against fire hazard, replace only with same type and rating of fuse.

For IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:

Caution:  Double pole / neutral fusing.

For all Models with Integral Lithium Battery:

Caution:  Danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type recommended by
the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Instructions d’installation et de sécurité

Pour les modèles sans interrupteur de courant:

La prise de courant d’alimentation sera installé près de l’équipement et sera accessible.

Pour les modèles avec un sélecteur d’alimentation 110V/220V:

Attention:  Avant de connecter l’appareil au circuit d’alimentation, le sélecteur de courant doit être positionné sur la sélection
appropriée correspondant au voltage du circuit de courant alternatif local.  Une mauvaise sélection peut engendrer des
dommages à l’appareil et créer un danger d’incendie.

Le sélecteur d’alimentation est un commutateur rond positionné près du connecteur
d’alimentation.  Il se représente comme suit:

A l’aide d’un tourne-vis plat ou d’une pièce de monnaie, le sélecteur peut être tourné dans la
position adéquate en veillaut que la flèche corresponde avec 110 ou 220, en fonction de la
valeur du circuit de courant local.  (Voir tableau ci-dessous)

Circuit local AC

Position Sélecteur

110 ~ 120 VAC

110

220 ~ 240 VAC

220

Pour tout les modèles:

Pas de composants à entretenir à l’intérieur.  Confiez toute réparation à un technicien qualifié.

Pour les modèles équipés de fusibles internes ou externes:

Afin d’éviter tout danger d’incendie, ne remplacer qu’avec le même type et la même valeur de fusible.

Pour IN2001 / IN3234 / IN3236 / IN3502 / IN3504 / IN3506 / IN3562 / IN3564 / IN3566 / IN3572 / IN3574 / IN3576:

Attention:  Double pôle / fusible au neutre.

Pour tout les modèles avec une batterie au lithium interne:

Attention:  Danger d’explosion si la batterie est incorrectement remplacée.  Ne remplacez la batterie qu’avec le même modèle,
ou avec un modèle recommandé par le constructeur.  Traitez les batteries usagées selon les instructions du fabricant, ou selon
les normes écologiques en viguer.

Summary of Contents for IN3262D

Page 1: ...OPERATION MANUAL IN3262D High Resolution VGA Distribution Amplifier IN3262DS High Resolution VGA Stereo Audio Distribution Amplifier ...

Page 2: ...ité Pour les modèles sans interrupteur de courant La prise de courant d alimentation sera installé près de l équipement et sera accessible Pour les modèles avec un sélecteur d alimentation 110V 220V Attention Avant de connecter l appareil au circuit d alimentation le sélecteur de courant doit être positionné sur la sélection appropriée correspondant au voltage du circuit de courant alternatif loca...

Page 3: ... durch den gleichen oder entsprechenden Typ wie vom Hersteller empfohlen Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers Instalacion E Instrucciones de Seguridad Modelos Sin Interruptor La conexión debe ser instalada cerca del equipo y debe ser accesible Modelos con Selector de Voltaje de 110 220V Precaución Antes de operar esta unidad el selector de voltaje debe instala...

Page 4: ...overning this device FCC COMPLIANCE This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide against harmful interference when equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance ...

Page 5: ...on with a wide range of scan rate compatible CRT LCD DMD ILA D ILA and HDLV plasma data and display devices In addition both units can be directly connect to MAC SUN SGI and other high resolution work stations and displays see list on page 5 for appropriate input and output adapter and extension cables Compatibility INPUT The IN3262D IN3262DS distribution amplifiers operate with specific video sig...

Page 6: ...d compatible data display to Output 2 using an IN8000 Series VGA Extension Cable available in lengths from 3 to 100 5 For the IN3262DS connect the audio stereo input cable IN9106 to the computer s audio output port The unit s audio outputs might be connected to a presentation monitor with built in speakers powered column speakers a sound system a VCR or audio recorder or a video conferencing syste...

Page 7: ...T OUTPUT 1 OUTPUT 2 Data Projector Presentation Monitor Sound System IN9204P 9V 500MA Power Supply CPU with VGA Port Local Monitor IN9106 Audio Cable 6 Detacable Cable Provided with Unit or IN8000 series VGA Extension Cable IN9045 IN8000 Cable Amplified Speakers IN8000 series VGA Extension Cable IN9106 Audio Cable ...

Page 8: ...o Gain 1 0 unity Bandwidth 400 MHz 3dB with 7 volt input signal Sync Signals TTL Sync both units pass sync in the same format as the input signal with sync polarities preserved Stereo Audio N A 2 3 5mm Stereo Mini Female line level Input Termination Internal Jumpers Red J 2 Green J 3 Blue J 4 Jumpers Closed default 75 ohm termination Jumpers Open High Z Monitor Emulation N A Internal Jumper J 26 J...

Page 9: ...ace ADAPTER EXTENTION CABLES FOR INPUT AND LOCAL MONITOR OUTPUT The IN3262D IN3262DS has 15 Pin HD VGA type connectors for input and local monitor output The following input and local monitor output cables are available Computer 3 6 12 25 VGA 15 Pin HD Input Cable IN8006 IN8012 IN8025 Output Cable Optional IN8006 IN8012 IN8025 MAC with 15 Pin D Input Cable IN9140 IN9144 Output Cable IN9141 IN9145 ...

Page 10: ...g Also inspect the cable to see if the coax may have been pinched or severed internally Try another cable The computer output is black and white when it should be color Solution There needs to be a termination on output 1 Use a local monitor or the IN9031 termination plug The output image of the IN3262D IN3262DS is visible but has poor quality low definition Solution The output cable may be too lo...

Page 11: ...hantibility or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully checked and is believed to be accurate However INLINE Inc assumes no responsibility for any inaccuracies that may be contained in this manual In no event will INLINE Inc be liable for direct indirect special incidental or consequential damages resulting from any...

Reviews: