background image

9

© 1999  -  INLINE, INC.                         

  IN3552R  /  IN3562R  OPERATION MANUAL  -  REV. 1.0  11/27/99 

WARRANTY

     

INLINE warrants the equipment it manufactures to be free from defects in materials and 
workmanship.

     

If equipment fails because of such defects and INLINE is notified within two (2) years from the
date of shipment, INLINE will, at its option, repair or replace the equipment at its plant, provided
that the equipment has not been subjected to mechanical, electrical, or other abuse or
modifications.

     

Equipment that fails under conditions other than those covered will be repaired at the current
price of parts and labor in effect at the time of repair.  Such repairs are warranted for ninety (90)
days from the day of re-shipment to the Buyer.

     

This warranty is in lieu of all other warranties expressed or implied, including without
limitation, any implied warranty or merchantibility or fitness for any particular purpose,
all of which are expressly disclaimed.

The information in this manual has been carefully checked and is believed to be accurate.  However,
Inline, Inc. assumes no responsibility for any inaccuracies that may be contained in this manual.  In no event will
Inline, Inc. be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect
or omission in this manual, even if advised of the possibility of such damages.  The technical information
contained herein regarding IN3552R / IN3562R features and specifications is subject to change without notice.

IBM is a registered trademark of International Business Machines.  Apple, MAC, Quadra, Centris, Performa, and
Powerbook are registered trademarks of Apple Computers, Inc.   All other trademarks and registered trademarks
are the property of their respective companies.

© Copyright 1999 - Inline, Inc.    All Rights Reserved

INLINE, INC.  

  22860 SAVI RANCH PARKWAY  

  YORBA LINDA, CA  92887

 800-882-7117    

     714-921-4100    

    FAX  714-921-4160    

    www.inlineinc.com

Summary of Contents for IN3552R

Page 1: ...Operation Manual 2 Input 1 Output Switcher Series IN3552R RGBHV Switcher IN3562R VGA Switcher ...

Page 2: ...ité Pour les modèles sans interrupteur de courant La prise de courant d alimentation sera installé près de l équipement et sera accessible Pour les modèles avec un sélecteur d alimentation 110V 220V Attention Avant de connecter l appareil au circuit d alimentation le sélecteur de courant doit être positionné sur la sélection appropriée correspondant au voltage du circuit de courant alternatif loca...

Page 3: ... durch den gleichen oder entsprechenden Typ wie vom Hersteller empfohlen Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers Instalacion E Instrucciones de Seguridad Modelos Sin Interruptor La conexión debe ser instalada cerca del equipo y debe ser accesible Modelos con Selector de Voltaje de 110 220V Precaución Antes de operar esta unidad el selector de voltaje debe instala...

Page 4: ...overning this device FCC COMPLIANCE This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide against harmful interference when equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance ...

Page 5: ...e units were primarily designed for use with high resolution RGB analog computer graphics type signals they may also be used to switch Composite Video S Video Y C Component Video or audio signals The IN3552R and IN3562R function very similarly utilizing the same front control panel and switching circuitry The main difference between the various models is the type of input output connectors on the ...

Page 6: ...lk screened on the bottom of the unit and can also be found on page 5 2 Connect the IN3552R IN3562R output to the display device 3 Apply AC power to the unit IN3552R Use IN7000 5 IN7100 5 IN7200 5 IN7300 5 Series 5 Conductor Cables available in a variety of lengths from 6 to 250 terminated with male BNC connectors IN3562R with VGA MAC SUN SGI 4 5 BNC computer graphics cards monitors and data displ...

Page 7: ...AC 230 VAC STAT IN3262 IN3262D IN8000 Series VGA Cable IN8000 Series VGA Cables IN3262 IN3262D HIGH RESOLUTION VGA DISTRIBUTION AMPLIFIER HIGH RESOLUTION VGA DISTRIBUTION AMPLIFIER 3262 3262 INPUT INPUT OUTPUT 1 OUTPUT 1 OUTPUT 2 OUTPUT 2 Data Projector Data Monitor PC with VGA Out PC with VGA Out Local Monitor Local Monitor ...

Page 8: ...evices REMOTE CONTROL OPERATION PIN FUNCTION 1 Input Select 2 Ground 3 Status The IN3552R IN3562R switchers have a REMOTE port a 3 pin captive screw connector which allows the units to be remotely controlled and also provides feedback to indicate which input is currently selected Input 1 or Input 2 can be selected through the remote port by providing a latching contact closure between the pin 1 an...

Page 9: ...n 1 grounded to Pin 2 Input 1 Selected MONITOR EMULATION IN3562R ONLY Some computer graphics cards must be connected to a local monitor in order to output a signal or select an appropriate resolution In order to ensure proper initialization of the graphics card at computer boot up a local monitor should be connected to each computer If that is not practical then the IN3562R monitor emulation dip s...

Page 10: ...V fuses Caution The case opening procedure should only be done by a qualified technician in a static free environment Failure to follow proper procedures could result in damage to the unit or electric shock Case Opening Procedure 1 Remove power from the unit 2 Loosen and remove the four case screws on the sides of the unit 3 Lift off the top half of the IN3552R IN3562R case Capacitor C1 may store ...

Page 11: ...ochrome with Sync Composite Video Y C Component Video Audio Output Connector type 5 BNC Female 15 Pin HD Female Bandwidth 650 MHz 7Vp p input signal 3dB 500 MHz 7Vp p input signal 3dB Isolation 60 dB 50 MHz 55 dB 75 MHz 50 dB 100 MHz Switching Time 2 5 mSec Typical Power Voltage 120 230 VAC 60 50 Hz Set at Factory Consumption 10 Watts Dimensions Size Height 1 65 4 2cm Width 8 5 21 6cm Depth 6 15 2...

Page 12: ...B VGA or MAC input or output cable may have a bad sync line Try running the sync through another cable The unit does not pass any signals Solution Verify that the unit is getting power by checking the front LEDs If no LED is on the AC power source may be faulty or the unit may have an internal problem Check the two internal 200mA fuses see Page 6 When controlling the switcher through the REMOTE CO...

Page 13: ...ntibility or fitness for any particular purpose all of which are expressly disclaimed The information in this manual has been carefully checked and is believed to be accurate However Inline Inc assumes no responsibility for any inaccuracies that may be contained in this manual In no event will Inline Inc be liable for direct indirect special incidental or consequential damages resulting from any d...