IN3606 / IN3656 / IN3666  OPERATION MANUAL  -  REV. 1.1  11/27/99

Programming Options

 RGB Delay

Only H and V inputs of a particular input is switched immediately. This is to allow for resizing and
syncing of monitors before the RGB picture elements are sent. The RGB inputs are switched a time
period afterwards. This time period is programmable in half second increments from one half second to
7.5 seconds. (See Programming Procedures)

 Vertical Interval Switching

Switching between inputs occurs during the vertical interval sync pulse therefore eliminating screen jitter
while switching.

Programming Procedures
There are two ways of programming the IN3600 Series. One is by RS232 communications, the other by
power up settings. Power up settings are accomplished by holding a particular input button while
simultaneously powering up the unit.

POWER ON SETTINGS

To Reset Unit to Factory Defaults - Hold down INPUT 1 button during power-up.
The default settings are:

Front Panel enabled
Vertical Interval Switching off
Master Switcher
1200 baud
“[ ]” command codes
Manual Switching (Scan off)
Blank sends nothing to output

To Set Miscellaneous Functions - Hold down INPUT2 button during power-up:

A.

 

BLANK LED goes solid

B.

 

Letting go of INPUT2, BLANK LED flashes

C.

 

Switches INPUT1 through INPUT4 are toggling options:
INPUT1 on = Vertical Switching on off = Vertical Switching off
INPUT2 on = Front Panel disabled off = Front Panel enabled
INPUT3 on = Auto Switching on

off = Auto Switching off

INPUT4 on = Sync on Blank

off = Nothing on Blank

D.

 

Depressing BLANK button saves this part of configuration and Blank LED flashes slower

E.

 

Switches INPUT1 and INPUT2 are alternate action selections:
INPUT1 on = Master mode
INPUT2 on = Slave mode

F.

 

Depressing BLANK button saves this part of configuration and Blank LED turns off.

Summary of Contents for IN3606

Page 1: ...Preliminary Operation Manual IN3600 Series 6 Input Switchers IN3606 RGBS Switcher IN3654 IN3656 RGBHV Switchers IN3666 VGA Switcher...

Page 2: ...de s curit Pour les mod les sans interrupteur de courant La prise de courant d alimentation sera install pr s de l quipement et sera accessible Pour les mod les avec un s lecteur d alimentation 110V...

Page 3: ...urch den gleichen oder entsprechenden Typ wie vom Hersteller empfohlen Entsorgung verbrauchter Batterien nur nach den Anweisungen des Herstellers Instalacion E Instrucciones de Seguridad Modelos Sin I...

Page 4: ...verning this device FCC COMPLIANCE This device has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provid...

Page 5: ...tely by using an optional IN3590 wired remote or a control system see Remote Control Operation on page 4 for more details The IN3600 Series Switchers offer easy operation and the following features 30...

Page 6: ...ked together in a Master Slave arrangement it is required that either all units be powered on simultaneously or that the Master unit be powered on last This is to allow the Master unit to poll all Sla...

Page 7: ...ut button while simultaneously powering up the unit POWER ON SETTINGS To Reset Unit to Factory Defaults Hold down INPUT 1 button during power up The default settings are Front Panel enabled Vertical I...

Page 8: ...s of delay can be programmed in F Depressing BLANK button saves configuration and Blank LED goes off To set RGB Delay Options Hold down INPUT4 button during power up A BLANK LED goes solid B Letting g...

Page 9: ...to the unit would look like BLANK0 Letters are not case sensitive and can be written as BLANK or blank Possible commands are ACI3 Set to 1200 Baud ACI4 Set to 2400 Baud ACI5 Set to 4800 Baud ACI6 Set...

Page 10: ...ol System many control systems are capable of providing contact closures Control Parameters In order to select a channel the channel select pin pins 1 6 must be connected to Common pin 7 or 8 The cont...

Page 11: ...5 BNC Female 15 Pin HD Female Bandwidth 300 MHz 3dB Isolation 60 dB 50 MHz 55 dB 75 MHz 50 dB 100 MHz Switching Time 3 0 mS Power Voltage 110 220 User Selectable Consumption 10 Watts Dimensions Size...

Page 12: ...f such defects and INLINE is notified within two 2 years from the date of shipment INLINE will at its option repair or replace the equipment at its plant provided that the equipment has not been subje...

Reviews: