Using the Utility 

Scenario:  

Devices A and B are located in Network N. Device C (the joiner) that is located in another network  attempts to join 
Network N. See  

Do as follows to add Device C to Network N using the Utility: 

 

Connect Device C to the network card of a PC. 

 

Open the Utility. The 

Main

 tab page displays information about Device C after connection succeeds. See 

Figure 

17

 

Click the 

Privacy

 tab page. Enter a name in the 

Private Network Name

 field. See 

Figure 18

 

Click 

Set  Local  Device  Only

.  When  the  page  as  shown  in 

Figure  19

  is  displayed,  the  setting  succeeds.  Now 

Device C has been removed from its logical network. 

 

Press the pushbutton on Device A or B for less than 3 seconds, making it the ‘adder’. 

 

Within 2 minutes, press the pushbutton on Device C (the ‘joiner’) for less than 3 seconds. 

 

Wait for connection to complete. 

 

The Power indicator on Device A (or Device B) and Device C will flash at 1 second intervals until the process succeeds 
or  fails.  It  will  illuminate  steadily  on  success.

 

If  an  error  occurs,  the  Power  indicator  on  Device  A  (or  Device  B)  and 

Device C will flash unevenly for 2 minutes. 

 

8

 

HOW TO IMPROVE THE TRANSMISSION CAPACITY 

It  is  important  to  use  the  PLC  product  complying  with  the  following  "correct  rules",  because  it  can  significantly 
improve the transmission capacity of the network. 

For  the  PLC  device  without  female  socket,  it  is  recommended  to  plug  the  device  directly  into  a  wall  socket,  not  to 
power stripe.  

 

Figure 21 Connecting the PLC device without the female socket 

 

 

×

×

Summary of Contents for PLC500M

Page 1: ...INN 001 InnboxPLC500M UM 01 EN 020 Adapter INNBOX PLC 500M User Manual Type of document User Manual Prepared for RC1011BX PI699E2 8P45A 3 Date 13 3 2014 Author Grega Smolej Uroš Habič ...

Page 2: ...nnboxPLC500M UM 01 EN 020 INN 001 The contents of this document are the property of Iskratel Kranj Slovenia and may not be copied reproduced or disclosed to a third party without written consent of the owner ...

Page 3: ... ADAPTER 7 3 1 The Ethernet Interface 7 3 2 The Adapter s Buttons 7 3 3 The Adapter s LEDs 7 5 HOW TO INSTALL THE UTILITY 9 6 HOW TO USE THE UTILITY 12 6 1 Main Tab 12 6 2 Privacy Tab 14 6 3 Diagnostics Tab 15 6 4 About Tab 16 7 FORMING A HOMEPLUG AV LOGICAL NETWORK 17 7 1 Using the Security Reset Pushbutton 17 7 2 Using the Utility 17 8 JOINING A NETWORK 18 8 1 Using the Security Reset Pushbutton...

Page 4: ......

Page 5: ...y power socket in the household can become a communication node Provides data connectivity to your routers computers and other networking devices in Plug and Play manner Provides power save mode where the output consumption of the device is less than 0 5W Up to 500Mbps physical data rate 1 2 Application High Definition HD and Standard Definition SD video distribution Higher data rate broadband sha...

Page 6: ...oduct should never be placed near or over a radiator or heat register Do not use an extension cord between the device and the AC power source Only a qualified technician should service this product Opening or removing covers may result in exposure to dangerous voltage points or other risks Do not plug the device into a power strip or surge protector because these devices may consist of filter and ...

Page 7: ...y Reset Set the status of the device members or restore the factory default settings Pressing and holding the Security Reset button for less than 3 seconds makes the adapter a member of the existing AV Logical Network AVLN Pressing and holding the Button for between 10 seconds and 15 seconds makes the adapter restore the factory default settings 3 3 The Adapter s LEDs All adapters LEDs are located...

Page 8: ...s normally Green Blink Device is resetting or device is in the process of password synchronization OFF The PLC adapter is powered off Ethernet Green ON Ethernet connection has established Green Blink Data is being transmitted OFF No Ethernet connection Data Green ON The PLC adapter has connected to the powerline network OFF The PLC adapter does not connect to the powerline network Note When data i...

Page 9: ...ollow the steps below to install the utility No password or CD Key is needed R 1 Please insert the utility CD into the computer s CD ROM drive Select the PLC 500AV Utility Installation folder and then double click the setup exe The page for installing the utility software is displayed Figure 4 Open the setup wizard R 2 Click Next to display the following page Figure 5 License agreement R 3 Select ...

Page 10: ...Kranj Slovenia and may not be copied reproduced or disclosed to a third party without written consent of the owner Figure 6 Selecting the folder R 4 Click Browse to select the installation folder and then click Next to continue Figure 7 Confirm installation R 5 Click Next to display the following page ...

Page 11: ...11 24 11 Figure 8 Completing the installation R 6 Click Close to finish the installation ...

Page 12: ...odically for other HomePlugAV devices connected to it If no local HomePlugAV device is discovered the status bar displays NO HOMEPLUG ADAPTERS DETECTED Figure 10 Main tab The lower panel displays all the HomePlugAV remote devices which are discovered in the current logical network The total number of remote devices connected in the same network is displayed above the remote device panel Network ty...

Page 13: ...ommon problems This process might take a few seconds to get completed Add This button is used to add a remote device to the existing network by entering the device password of the device A dialog box appears Figure 12 You can enter a device name and the password If the device is found and the password is entered correctly a confirmation box appears If a device is not found a message appears provid...

Page 14: ...the network name changes to anything other than HomePlugAV the network type in the main screen is displayed as Private Set Local Device Only This button is used to change the network name and password of the local device If a new network password is entered all the devices appeared in the main panel prior to this are no longer present in the new network effectively making the local devices not to ...

Page 15: ...e Lower panel displays the history of all remote devices appeared on the computer over a certain period of time All the devices and the parameters of the devices on the powerline network are listed Devices that are active on the current logical network show a transfer rate in the rate column Devices on other networks or devices that no longer exist are shown with a in the rate column The following...

Page 16: ...ed to a third party without written consent of the owner 5 4 About Tab The About screen shows the software version and provides an html link to a website such as http www qua qualcomm com Clicking the web address you can visit the web site Figure 15 About tab Preferences The lower part of the panel displays options for turning the autoscan function on or off ...

Page 17: ...ess than 3 seconds The button on B must be pressed within 2 minutes STEP 3 Wait for connection to complete The Power indicator on both devices will flash evenly at 1 second interval until the operation succeeds or fails The Power indicator will illuminate steadily on successful completion If an error occurs the Power indicator on both devices will flash unevenly for 2 minutes 6 2 Using the Utility...

Page 18: ... logical network AVLN using the Security Reset pushbutton and using the Utility Operation progress and outcome can be monitored by observing the behavior of the power LED 7 1 Using the Security Reset Pushbutton Scenario Devices A and B are located in network N Device C the joiner that is not located in any networks attempts to join Network N Any devices on Network N can become the adder Figure 20 ...

Page 19: ...n on Device A or B for less than 3 seconds making it the adder Within 2 minutes press the pushbutton on Device C the joiner for less than 3 seconds Wait for connection to complete The Power indicator on Device A or Device B and Device C will flash at 1 second intervals until the process succeeds or fails It will illuminate steadily on success If an error occurs the Power indicator on Device A or D...

Page 20: ...64bit PLC PHY Rate 500Mbps Max Modulation Band 2 68MHz Modulation Schemes Supports OFDM 4096 1024 256 64 16 8 QAM QPSK BPSK and ROBO Encryption 128 AES LED s Power Ethernet Data Push Button Reset Restore the factory default settings Security Set the network password automatically Consumption 3W Operating Temperature 0ºC to 40ºC Storage Temperature 20ºC to 70ºC Operating Humidity 10 to 90 non conde...

Page 21: ... Avoidance DAK Device Access Key DM Device Manager IGMP Internet Group Management Protocol NEK Network Encryption Key NID Network ID Identification NMK Network Membership Key PLC Powerline Communication PIB Parameter Information Block STA Station a STA in the network with a connection to the powerline and being able to source or sink traffic TDMA Time Division Multiple Access TEI Terminal Equipmen...

Page 22: ...ckets that do not have a VLAN TAG The settings are available for Unicast directed to a host IGMP default CAP 3 sets the channel access priority for IGMP frames these are the group management frames not the stream data Unicast default CAP 1 sets the default channel access priority for unicast frames not matching any other classification or mapping IGMP managed Multicast Stream Fixed to CAP 2 sets t...

Page 23: ......

Page 24: ...4 Iskratel d o o Kranj Innbox Business Unit Ljubljanska c 24a SI 4000 Kranj Slovenia phone 386 0 4 207 2000 fax 386 0 4 207 2712 e mail info innbox net web www innbox net INN 001 InnboxPLC500M UM 01 EN 020 ...

Reviews: