background image

Sound

Meaning

Course of Action

Intelligent Heat Sensor:  

a short beep every few

seconds, then fast ‘beep, 

beep, beep’ 

The Stove Guard has 

detected a risk situation 

and turns the cooker off.

Wait until the cooker cools down 

to a safe level. The cooker can 

be used again when the Control 

Unit (behind the cooker) stops 

signalling and the cooker lights 

turn on. If the alarm was triggered 

by normal cooking, see FAQ 

(chapter 4) in the main manual, 

question 2.1.

Control Unit:  

a short buzzing sound at 

approximately 5 second 

intervals

or a continuous buzzing 

sound

The cooker has been  

turned off.

Wait until the cooker cools down 

to a safe level. The cooker can 

be used again when the Control 

Unit (behind the cooker) stops 

signalling and the cooker lights 

turn on. If the Control Unit does 

not stop signalling, see FAQ 

(chapter 4) in the main manual, 

question 4.1.

Control Unit:  

a short buzzing sound 

and a long buzzing sound, 

alternating at 5 second 

intervals 

The cooker has been turned 

off due to a temporary error 

or a fault in the system 

(automatic fault diagnosis).

Press the Heat Sensor cover once. 

If this does not silence the alarm, 

see FAQ (chapter 4) in the main 

manual, question 5.1.

Intelligent Heat Sensor 

and Control Unit:  

A beep from the Sensor 

and a buzz from the Control 

Unit sounds  once a minute

Heat Sensor is at the end of 

its useful life.

The Heat Sensor needs to be 

replaced (see the main manual 

chapter 6). Pressing the Heat 

Sensor cover delays the alarm for 

12 hours. 

When the battery has run 

out the cooker can only be used for 

5 minutes at a time (EU standard 

requirement).

l

  Using a pot much smaller than a 

hotplate can trigger an alarm. 

l

  

It is recommended to use a lid  

when possible.

l

  

For more information see FAQ 

question 2.1 (in the main manual). 

The Stove Guard does not cover all possible hazardous situations but 

significantly increases the safety of a cooker. Never leave the cooker 

unattended on purpose. 

Maintenance:

 Due to the automatic fault diagnosis, the Stove Guard does 

not need maintenance or testing. 

Optional features

Tick the box if in use

  

3

For full description of Stove Guard features, see the main manual chapter 2.1. 

   A carbon monoxide / smoke alarm is used in 

conjunction with the Stove Guard. 

What do the alarm signals mean?

The Intelligent Heat Sensor is above the cooker:  

the alarm signal is a high-tone beep.

The Control Unit is behind the cooker:  

the alarm signal is a low buzz.

Reviews: