6.8.3
Flashing the firmware/rescue procedure
Objective
The entire firmware of the mGuard should be reloaded on the device.
–
All configured settings are deleted.
The mGuard is set to the delivery state.
–
In Version 5.0.0 or later of the mGuard, the licenses installed on the mGuard are re-
tained after flashing the firmware. Therefore, they do not have to be installed again.
Possible reasons
The administrator and root password have been lost.
Requirements
Action
•
Hold down the Reset button until the LEDs light up green. Then, the mGuard is in the
recovery state.
•
Release the Reset button within a second of entering the recovery state.
If the Reset button is not released, the mGuard is restarted.
The mGuard now starts the recovery system: It searches for a DHCP server via the LAN
interface in order to obtain an IP address.
The middle LED flashes.
The “install.p7s” file is loaded from the TFTP server or SD card. It contains the electron-
ically signed control procedure for the installation process. Only files that are signed are
executed.
The control procedure deletes the current contents of the Flash memory and prepares
for a new firmware installation.
The three green LEDs form a running light.
The “jffs2.img.p7s” firmware file is downloaded from the TFTP server or SD card and
written to the Flash memory. This file contains the actual mGuard operating system and
is signed electronically. Only files signed by Innominate are accepted.
This process takes around 3 to 5 minutes. The middle LED is lit continuously.
The new firmware is extracted and configured. This procedure takes 1 to 3 minutes.
•
As soon as the procedure is complete, all LEDs flash green simultaneously.
•
Restart the mGuard. To do this, briefly press the
Reset button
.
Alternatively, you can disconnect and insert the USB cable, as it is only used for the
power supply.
The mGuard is in the delivery state. You can now configure it again (see “Establishing a
local configuration connection” on page
117):
NOTE:
To flash the firmware, a DHCP and TFTP server or a BootP and TFTP server must
be installed on the locally connected computer.
Install the DHCP and TFTP server, if necessary (see “Installing the DHCP and TFTP serv-
er” on page
258).
NOTE:
Installing a second DHCP server in a network could affect the configuration of the
entire network.
NOTE:
Do not interrupt the power supply to the mGuard during any stage of the flashing
procedure. Otherwise, the device could be damaged and may have to be reactivated by
the manufacturer.
Summary of Contents for mGuard
Page 6: ...Innominate Security Technologies...
Page 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Page 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Page 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Page 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Page 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Page 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Page 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Page 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Page 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...