1.3.2
Connecting to the network
•
Connect the mGuard to the network. To do this, you need a suitable UTP cable (CAT5)
which is not included in the scope of supply.
•
Connect the internal network interface LAN 1 of the mGuard to the corresponding
Ethernet network card of the configuration computer or a valid network connection of
the internal network (LAN).
1.3.3
Service contacts
A
push button
or an
on/off switch
(e.g., key switch) can be connected between
service
contacts CMD V+ and CMD
.
The
contacts ACK (+)
and
FAULT (+)
are non-floating, continuously short-circuit-proof
and supply a maximum of 250
mA.
NOTE:
Only connect the mGuard network ports to LAN installations. Some telecommuni-
cations connections also use RJ45 sockets; these must not be connected to the RJ45
sockets of the mGuard.
NOTE:
Do
not
connect the voltage and ground outputs (GND, CMD V+) to an external
voltage source.
Please note that only the “Service 1” contacts are used with firmware version up to and
including 7.6x. The “Service 2” contacts shall be made available as of firmware version
8.1.
The plug-in screw terminal blocks of the service contacts may be removed or inserted dur-
ing operation of the mGuard.
mGuard
rs4000
mGuard
rs2000
Service 1 + 2
CMD V+
CMD
GND
ACK
Power
P1+
GND
P2+
GND
Voltage out-
put (+)
Supply volt-
age
Switching
input 11 ...
36
V
DC
Ground out-
put (-)
Supply volt-
age
Short-cir-
cuit-proof
switching
output
*
+24 V
0 V
+24 V
0 V
See Section
1.3.4
Only
for
mGuard
rs4000
See Section
1.3.4
Contact
GND
AUX
GND
FAULT
Example
Example
Not used
Not used
Signal out-
put (-)
Signal out-
put (+)
†
*
Maximum of 250 mA at 11 ... 36 V
DC
†
11
V
...
36
V when operating correctly; disconnected in the event of a fault
Summary of Contents for mGuard
Page 6: ...Innominate Security Technologies...
Page 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Page 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Page 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Page 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Page 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Page 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Page 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Page 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Page 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...