mGuard
rs4000/rs2000
Switch
36
Innominate Security Technologies
I15007_en_02
2.2
Startup
2.2.1
Safety notes
To ensure correct operation and the safety of the environment and of personnel, the device
must be installed, operated, and maintained correctly.
General notes regarding usage
2.2.2
Checking the scope of supply
Before startup, check the scope of supply to ensure nothing is missing.
The scope of supply includes:
–
Device
–
Package slip
–
Plug-in screw terminal blocks for the power supply connection and inputs/outputs (in-
serted)
2.2.3
mGuard-Firmware
The device must be operated with mGuard-Firmware version 8.1.5 or higher.
NOTE:
Risk of material damage due to incorrect wiring
Only connect the device network ports to LAN installations. Some telecommunications
connections also use RJ45 sockets; these must not be connected to the RJ45 sockets of
the device.
For connecting a modem or serial terminal to the RS-232 interface, you will need a null
modem cable not exceeding 10
m in length.
NOTE:
Risk of damage to equipment due to noise emissions
This is a Class A item of equipment. This equipment can cause radio interference in resi-
dential areas; in this case, the operator may be required to implement appropriate mea-
sures.
NOTE:
Electrostatic
discharge
When handling the device, observe the necessary safety precautions against electrostat-
ic discharge (ESD) in accordance with EN
61340-5-1 and IEC
61340-5-1.
NOTE:
Select suitable ambient conditions
–
Ambient temperature:
-20°C
...
+60°C
–
Maximum humidity, non-condensing:
5%
...
95%
To avoid overheating, do not expose the device to direct sunlight or other heat sources.
NOTE:
Cleaning
Clean the device housing with a soft cloth. Do not use aggressive solvents.
Summary of Contents for mGuard
Page 6: ...Innominate Security Technologies...
Page 32: ...mGuard rs4000 rs2000 32 Innominate Security Technologies I15007_en_02...
Page 74: ...mGuard rs4000 rs2000 3G 74 Innominate Security Technologies I15007_en_02...
Page 108: ...mGuard pci SD 108 Innominate Security Technologies I15007_en_02...
Page 142: ...mGuard centerport 142 Innominate Security Technologies I15007_en_02...
Page 156: ...mGuard delta 156 Innominate Security Technologies I15007_en_02...
Page 180: ...mGuard pci 180 Innominate Security Technologies I15007_en_02...
Page 196: ...mGuard blade 196 Innominate Security Technologies I15007_en_02...
Page 236: ...mGuard industrial rs 236 Innominate Security Technologies I15007_en_02...
Page 254: ...EAGLE mGuard 254 Innominate Security Technologies I15007_en_02...