5
DE
AIO-GLEIT-20-A4 / Version 180111 / www.innotech.at
3
SAFETY INSTRUCTIONS
3.2
FOR FITTERS: FOR SAFE INSTALLATION
3.3
FOR USERS: FOR SAFE USE
-
Stainless steel may not come into contact with sanding dust or steel tools, as this
can lead to corrosion.
-
All stainless steel screws are to be treated with an appropriate lubricant before
installation.
-
The fitter must ensure that the substructure is appropriate for the fastening of the
fall prevention system. In case of doubt, consult a structural engineer.
-
The roof covering must be sealed according to the appropriate regulations.
-
Proper fastening of the safety system must be documented with fastening reports
and photos of the respective circumstances of installation.
-
Attachment to the fall protection system is completed INNOTECH cable sliders (e.g.
AIO-GLEIT-10, -11, -12, -13 or -20). The INNOTECH cable slider may only be used
together with original carabiners, the INNOTECH "ALLinONE" horizontal lifeline sys-
tem and personal protective equipment in accordance with EN 361 (safety harness)
and EN 363(fall arrest system).
-
The minimum free space necessary under the edge is calculated as follows: Defor-
mation of the anchor device in case of manufacturer's specification of the
personal protective equipment used, including deflection of the cable + body height
+ 1 m safety margin.
-
For horizontal use, only such connecting elements can be used which are designed
for this purpose and tested for the respective edge type (sharp edges, trapezoidal
sheet, steel girders, concrete, etc.).
-
Proper use of the individual components, including the "Personal Protective Equi-
pment" must be ensured, since the effectiveness of the fall prevention system is
otherwise NOT guaranteed.
-
Do NOT use fall arrest systems if wind speeds exceed normal parameters.
-
On slanted roofs, the proper snow-catching features must be added to prevent ice or
snow from sliding from the roof surface.
Should any confusion arise during installation, the manufacturer
must be contacted.