background image

 

Error 

Code 

Error Code Indication 

TROUBLE SHOOTING 

01 

Wire Controller EEPROM Error 

A. Check EEPROM chip on wire controller PCB is 

loose,; B. After step A, if unit still displays error 

code E01, change the wire controller. 

02 

Indoor Unit PCB EEPROM Error 

A. Check EEPROM chip on indoor unit PCB is 

loose, the chip location on12KBUT/18KBTU model 

PCB is IC11, on 24KBTU/36KBTU model PCB is 

IC7; B. After step A, if unit still displays error code 

E02, change the indoor unit PCB. 

03 

SIGNAL COMMUNICATION 

BETWEEN OUTDOOR UNIT MAIN 

PCB AND INVERTER MODULAR 

BOARD 

A. Check the wiring on outdoor unit main PCB is 

correct or loose; B. If step A is passed, then change 

outdoor unit main PCB; C. If step A does not pass, 

change outdoor unit inverter modular board. 

05 

OUTDOOR UNIT FAN COIL 

TEMPERATURE SENSOR 

FAILURE 

A. Connection location on outdoor unit main PCB 

is: 

CN15 PO\PG\PQ 

for 12kbtu/18kbtu/ 

24kbtu/36kbtu, PO is for outdoor ambient 

temperature sensor, PG is for outdoor fan coil 

temperature sensor, PQ is for outdoor unit discharge 

gas temperature sensor. Replace with new sensor; B. 

after step A, if unit still displays error code E05, 

change the outdoor unit main PCB. 

06 

OUTDOOR UNIT AMBIENT 

TEMPERATURE SENSOR 

FAILURE 

A.  Connection  location  on  outdoor  unit  main 

PCB  is: 

CN15  PO\PG\PQ 

for  12kbtu/18kbtu/ 

24kbtu/36kbtu,  PO  is  for  outdoor  ambient 

temperature  sensor,  PG  is  for  outdoor  fan  coil 

temperature  sensor,  PQ  is  for  outdoor  unit 

discharge  gas  temperature  sensor.  Replace  with 

new  sensor; B. after  step A, if  unit  still displays 

error  code  E06,  change  the  outdoor  unit  main 

PCB. 