DRY
A humidity sensor allows every single ventilation
unit to detect the environmental humidity, and in
case of necessity, to activate independently of the
high-speed air extraction cycles to reduce the
moisture and improve the environmental comfort.
Depending on the ambient humidity conditions, the
procedure may have a duration of between 2 ÷ 12
minutes (during which the communication with the
remote control is inhibited) and can be repeated at
hourly intervals. The drying cycle is suspended in
"night mode."
Note:
This feature is disabled by default; to enable
par.fo see "Parameter Settings".
dehumidification function
BRIGHTNESS
SENSOR
'
A light sensor allows every single ventilation units
alone to adopt the minimum speed (extra-low)
during the night. If necessary, the brightness
sensors can be excluded; in this case the night mode
can only be activated manually by means of the
remote control button.
Note:
This feature is disabled by default; to enable
par.fo see "Parameter Settings".
brightness sensor function '
5.4 SETTING THE PARAMETERS (THRESHOLD HUMIDITY 'OPERATION AND ACTIVATION LIGHT)
- VERSION -
1
Press the AUTO button when held up
in that the central LED does not blink fast.
The central signaling LED will flash '
rapidly as shown in the illustration
which indicates the parametetri configuration.
Now it will be possible to set:
-the level of humidity for dehumidification function
-l'attivazione or deactivation of the light function
Login procedure parameter configuration