Innova S.r.l.
Pag. 11
N420229A_ManualHRW_rev2.en.docx
2
INSTALLATION
2.1.1
INSTALLATION CONDITI ONS
The unit must be installed according to national and local rules governing the use of electrical devices and according to the following
guidelines:
install the unit within residential buildings with ambient temperature between 0 ° C and 45 ° C;
avoid areas in close proximity to sources of heat, steam, flammable and / or explosive and particularly dusty areas;
install the unit in a place not subject to frost (the condensation water must be discharged not frozen, at a certain inclination, using a
siphon);
not install the unit in areas with a high relative humidity (such as the bathroom or toilet) to avoid condensation on the outer
surface;
choose an installation place where there is enough space around the unit for the air ducts and connections in order to perform
maintenance;
the consistency of the ceiling / wall / floor where the unit will be installed must be adapted to the weight of the unit and does not
cause vibrations.
In the environment chosen for the installation must be present:
-Connections of the air ducts;
-Connection to 230V single phase electric
-Connection to drain condensate
hydraulic connection