background image

1.

Plug the BLACK test lead into "COM" jack of the multimeter; plug the RED
test lead into the "V" jack.

2.

Set the meter’s Function/Range Selector Switch to the appropriate ACV or
DCV position as desired.

3.

Place the RED test lead onto the positive (+) side of the item being tested
and the BLACK test lead onto the negative (-) (across the source/load) side
of the item. BE CAREFUL not to touch any energized conductors with any
part of your body.

4.

Read the results on the display.

B. RESISTANCE MEASUREMENT 

(OHMS)

1.

Plug the RED test lead into the "

" jack of the multimeter; plug the BLACK

test lead into the "COM" jack.

2.

Set the meter’s Function/Range Selector Switch to the OHM  "

" range

function.

3.

Place the RED test lead onto one side of the item being tested and the
BLACK test lead onto the other side of the item. (Polarity does not matter
when checking resistance).

4.

Read the results on the display.

C. DIODE TEST

1.

Plug the RED test lead into the 

jack of the multimeter; plug the BLACK

test lead into the "COM" jack.

2.

Set the meter’s Function/Range Selector Switch to the 

position.

3.

Place the RED test lead onto one side of the diode being tested and the
BLACK test lead onto the other side.

4.

Read the results on the display.

5.

Reverse the test leads and again read the results on the display. Compare
the two readings. One reading should indicate a voltage drop value; the
other reading should indicate an overrange (1) condition.

D. DC CURRENT MEASUREMENT (AMPS)

1.

Plug the RED test lead into the "mA" or the "DC10A" jack of the multime-
ter, as applicable; plug the BLACK test lead to the "COM" jack.

2.

Set the meter's Function/Range Selector Switch to the appropriate Amps
range position as desired.

To measure from 0 to 200mA, set the Selector Switch to the desired
"DCmA" position.

To measure from 200mA to 10 Amps DC, set the Selector Switch to the
"DC10A" position.

3.

Disconnect the battery, or shut off the power to the circuit being tested.

4.

Disconnect one end of the wire or device, from the circuit where current will
be measured.

5.

Place the RED test lead on the disconnected wire and place the BLACK
test lead at the location from which the wire was disconnected (series con-
nection).

6.

Reconnect the battery, or apply power to the circuit being tested.

7.

Read the results on the display.

CAUTION: After the test is completed, shut the power off to the circuit

before removing the test leads and before reconnecting any disconnected
wires or devices.

E. BATTERY TEST

1.

Plug the RED test lead into the "BAT." jack of the multimeter; plug

the

BLACK test lead into the "COM" jack.

2.

Determine the voltage rating of the battery to be tested.

3.

Set the meter’s Function/Range Selector Switch to the desired "Battery
Test
" range.

4.

Place the RED test lead on the positive post of the battery under test; place
the BLACK lead on the negative post.

5.

Read the results on the display.

MAINTENANCE

1.

No periodic maintenance is required other than the replacement of the battery,
the fuse, and visual inspection of the meter.

2.

Keep the meter clean and dry. DO NOT use solvent to clean, use a damp
(not wet) cloth and fully dry after cleaning.

BATTERY AND FUSE REPLACEMENT

1.

Turn the Digital Multimeter “OFF” and remove the test leads.

2.

Remove the two screws on the back of the meter and separate the case.

3.

Replace the fuse or battery as necessary:

For battery replacement: Remove the battery from the battery com-
partment and replace only with one 9-volt alkaline battery.

For fuse replacement: Remove the fuse from the fuse holder and
replace with a 0.315A/250V - UL Listed Bussmann, GMA Type
(Radio Shack GMA/270 series; #270-1046 ) 
fuse.

NOTE: Use a 0.315A/250V, 5x20mm type fuse ONLY - Bussmann, GMA Type

(Radio Shack #270-1046 or similar). Using an incorrect fuse may result in seri-
ous injury and/or damage to the unit.

4.

Reassemble the case and secure with the two screws.

LIMITED ONE YEAR WARRANTY

The Manufacturer warrants to the original purchaser that this unit is free of
defects in materials and workmanship under normal use and maintenance for
a period of one (1) year from the date of original purchase. If the unit fails with-
in the one (1) year period, it will be repaired or replaced, at the Manufacturer’s
option, at no charge, when returned prepaid to the Service Center with Proof
of Purchase. The sales receipt may be used for this purpose. Installation labor
is not covered under this warranty. All replacement parts, whether new or
remanufactured, assume as their warranty period only the remaining time of
this warranty. This warranty does not apply to damage caused by improper
use, accident, abuse, improper voltage, service, fire, flood, lightning, or other
acts of God, or if the product was altered or repaired by anyone other than the
Manufacturer’s Service Center. The Manufacturer, under no circumstances
shall be liable for any consequential damages for breach of any written war-
ranty of this unit. This warranty gives you specific legal rights, and you may
also have rights, which vary from state to state. This manual is copyrighted with
all rights reserved. No portion of this document may be copied or reproduced
by any means without the express written permission of the Manufacturer.
THIS WARRANTY IS NOT TRANSFERABLE. For service, send via U.P.S. (if
possible) prepaid to Manufacturer. Allow 3-4 weeks for service/repair.

SERVICE PROCEDURES

If you have any questions, require technical support or information on
UPDATES and OPTIONAL ACCESSORIES, please contact your local store,
distributor or the Service Center.

USA & Canada:

Technical Service Center
17291 Mt. Herrmann Street
Fountain Vally, CA 92708 U.S.A.

(800) 544-4124 (6:00 AM-6:00 PM, Monday-Friday PST)

All others: (714) 241-6802 (6:00 AM-6:00 PM, Monday-Friday PST)

FAX: (714) 432-7511 (24 hr.)

Web: www.iEQUUS.com

- 3 -

- 4 -

© Innova 2006

WARNING 

Resistance measurements must be made on "de-energized" (dead) cir-
cuits ONLY. Impressing a voltage across the multimeter's terminals while
set to any resistance range may result in electric shock, instrument dam-
age and/or damage to equipment under test. MAKE SURE equipment is
completely de-energized before taking any resistance measurements.

WARNING 

To avoid electrical shock and/or damage to the multimeter, ensure the
power is removed from the circuit before any DIODE testing procedure is
conducted. Test diodes on de-energized (dead) circuits only, never on live
circuits.

WARNING 

To prevent electrical shock when performing current measurements,
follow all steps as indicated below DO NOT skip any steps or take any
short cuts.

The DC10A range is not fused. To avoid current hazard and/or damage
to the tester, DO NOT try to take measurements on circuits that have
more than 10 amps. DO NOT take more than 15 seconds to take the
reading. A waiting period of AT LEAST 15 MINUTES is necessary
between every 15 second testing period.

WARNING 

When replacing the battery or the fuse, remove only the rear panel. Do
not remove or disassemble the circuit board or the front panel, these
items are not serviceable and if disassembled there is the possibility of
loose metal parts shorting the circuit board and causing an electrocu-
tion danger to the user.

Reviews: