With tape material along the wire wrapped, sealed wiring holes, prevent the condensed water and insects.
●
Tightly
secure
the
power
source
wiring using
the
cord
clamp
inside
the
unit
.
NOTE
:
Fix
the
rubber
bushes
with
adhesive
when conduit
tubes
to
the
outdoor
unit
are
not
used
.
WARNING
CAUTION
Stand the cylinder upright when filling.
There is a siphon pipe inside,so the cyliner
need not to be upside-down to fill with liquid.
Turn
the cylinder upside -down when filling.
Stand the cylinder upright when filling.
Additional
r
efrigerant
c
harge
Filling a cylinder with an attached siphon
Filling other cylinders
The unit has been filled with refrigerant.
Please according “Piping
Requirement” to calculate additional charge.
After vacuum pump procedure has been finished, first exhaust air from charge hose, then open valves, charge
refrigerant as “liquid” type through Liquid stop valve.
At the end, please close valves and record
the
refrigerant charging quantity
.
Wiring
10
危
险
!
CAUTION
Installation instructions
(1)
For 18K~36K models, each
pipelines
needs
to be evacuated individually.
For 42K, only need to vacuum at the main stop valve.
(2) An
excess
or
a
shortage
of
refrigerant
is
the
main cause
of
trouble
to
the
unit
.
Charge
the
correct
refrigerant
quantity
according to
the
description
of
label
at
the
inside
of
the
manual
.
(3) Check
refrigerant
leakage
in
detail
.
If
a
large refrigerant
leakage
occurs
,
it
will
cause
difficulty with
breathing
or
harmful
gases
will
occur
if
a fire
is
being
used
in
the
room
.