2.3.3 Set Operating Mode
The third dip switch and the fourth dip switch are selecting the operating mode. Standard mode is the
conventional mode.
By setting the strong mode dip switches of the condensing unit, the air conditioner can quickly increase the
capacity output and ensure reliable operation in a short time, so as to meet the user's demand for the indoor
temperature to quickly reach the set temperature.
Energy saving mode is achieved by setting the condensing unit operating mode to operate the air
conditioner within a small load range.
Operating mode
Outdoor unit dip switches
Standard mode (Default)
Strong mode
Energy saving mode
2.3.4 Set Indoor Fan Speed
Set the indoor fan speed through the eight dip switches of the indoor main control board. The higher level,
the higher speed of the indoor unit fan.
Capacity
24K indoor unit dip switches
36K indoor unit dip switches
Level 1
(Default)
Level 2
SERVICE MANUAL
11